Uline H-1114 Manual Del Usuario página 3

Ocultar thumbs Ver también para H-1114:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

SETTING "LBS" OR "KG"
1.
For lb., press UNIT WEIGHT PRESET, then 1.
2. For kg., press UNIT WEIGHT PRESET, then 2.
3. Scale displays weight in "kg" or "lb" until you change
it.
NOTE: If UNIT WEIGHT PRESET is set to select unit
weight as a secondary function, hold key for
about 3 seconds.
ZERO DISPLAY MASK (BACK ZERO MODE)
Auto zero tracking (default) ensures that the "0" remains
stable despite changes in temperature or power. In
drafty and other unstable conditions, the Zero Display
Mask is useful. You can set the scale to not show the first
division of weight. It will show "0," as long as the weight is
less than two display divisions.
0 = Normal Mode (1st Division displayed)
1 = Zero Display Mask (1st Division displayed as 0)
1.
Press ZERO, then 8.
WEIGHT
- -
1
SMPL
→ 0←
-
WT
PC
NET
NET
WT
2. Press 4 to select 0, or 6 to select 1.
3. Press QTY PRESET to exit and save the settings.
DISPLAY BACKLIGHT
Turn Backlight On:
Press ZERO, then 5. Backlight turns on automatically
when any key is pressed or the weight is over 10
divisions. When weight is removed, backlight switches
off after 5 seconds.
Backlight On Continuously:
Press ZERO, then 4. Backlight will now stay on all the time.
Backlight Off:
Press ZERO, then 6. Turns backlight off.
SET SAMPLING SPEED
The slower the sampling speed, the more accurate the
count will be. The faster the sampling speed, the less
accurate the count may be.
01 to 15 (01 = slow, 15 = very fast)
PAGE 3 OF 30
SETTING FUNCTION MODES
UNIT WEIGHT
QUANTITY
08
M+
STABLE
1.
Press ZERO, then 8.
WEIGHT
- -
1
→ 0←
-
NET
NET
2. Press 8 to increase or 2 to decrease the sampling
speed.
3. Press QTY PRESET to exit and save the settings.
PRESET TARE
You can set the preset tare (used to enter the weight of
a container when its weight is known) one of two ways:
0 = Preset tare function is not available when an
object is on the scale.
1 = Preset tare function is available when an
object is on the scale.
1.
Press ZERO, then 1, 2.
WEIGHT
USEr
→ 0←
NET
NET
Pcs
.
2. Press 0 or 1 to select the desired mode.
3. Press
to exit and save the settings.
PRESET QUANTITY
You can set the way the scale will accept preset
quantities.
0 = Scale accepts quantity only when weight is
stable.
1 = Scale accepts quantity even when weight is
unstable.
1.
Press ZERO, then 1, 3.
WEIGHT
USEr
→ 0←
NET
NET
.
2. Press 0 or 1 to select the desired mode.
3. Press
to exit and save the settings.
UNIT WEIGHT
SMPL
M+
WT
PC
STABLE
WT
UNIT WEIGHT
PttYP
SMPL
M+
WT
PC
STABLE
WT
UNIT WEIGHT
0.tYtP
SMPL
M+
WT
PC
STABLE
WT
QUANTITY
08
Pcs
QUANTITY
X
Pcs
QUANTITY
X
Pcs
1119 IH-1114
Tabla de contenido
loading

Este manual también es adecuado para:

H-1115H-1116H-1117

Tabla de contenido