(e) Live cable indicator
(f) Temperature monitoring indicator
(g) Battery indicator
(h) Measuring indicator
(i) Fine scale
Technical data
Digital detector
Article number
A)
Max. detection depth
– Ferrous metals
– Non-ferrous metals (copper)
– Live wires 110−230 V (with
B)
voltage applied)
Operating temperature
Storage temperature
Inductive sensor
– Operating frequency range
– Max. magnetic field strength
(at 10 m)
Max. altitude
Relative air humidity max.
Pollution degree according to
IEC 61010-1
Battery
Approx. operating time
Weight according to EPTA-Proced-
ure 01:2014
Dimensions (length × width × height)
Protection rating
A) Depends on material and size of the objects, as well as material
and condition of the substrate
B) Lower detection depth with non-live wires
C) Only non-conductive deposits occur, whereby occasional tem-
porary conductivity caused by condensation is expected.
The serial number (8) on the type plate is used to clearly identify your
measuring tool.
The accuracy and detection depth of the measuring
u
result may be negatively affected if the condition of
the substrate is unfavorable.
Assembly
Inserting/Changing the Battery
It is recommended that you use alkaline manganese batter-
ies to operate the measuring tool.
To open the battery compartment cover (9), push the lock-
ing mechanism (10) in the direction of the arrow and lift the
battery compartment cover. Insert the battery.
Bosch Power Tools
When inserting the batteries, ensure that the polarity is cor-
rect according to the illustration on the inside of the battery
compartment.
Take the battery out of the measuring tool if you do
u
not intend to use the tool for a long time. When it is
stored in the measuring tool for longer periods, the bat-
tery can corrode and discharge itself.
Battery indicator
GMS 100 M
The battery indicator (g) on the display always indicates the
3 601 K81 100
current battery status:
Display
100 mm
80 mm
50 mm
–10 °C to +45 °C
–20 °C to +70 °C
Operation
Protect the measuring tool from moisture and direct
u
5 ± 0.2 kHz
sunlight.
72 dBµA/m
Do not expose the measuring tool to any extreme tem-
u
peratures or variations in temperature. In case of
2000 m
large variations in temperature, leave the measuring
80 %
tool to adjust to the ambient temperature before
switching it on. The accuracy of the measuring tool and
C)
2
the functionality of the display may be compromised if ex-
posed to extreme temperatures or variations in temperat-
1 × 9 V 6LR61
ure.
5 h
Avoid hard knocks to the measuring tool or dropping
u
0.26 kg
it. After severe external influences and in the event of ab-
normalities in the functionality, you should have the
measuring tool checked by an authorised Bosch after-
200 × 86 × 32 mm
sales service agent.
IP 54 (dust and
Certain ambient conditions fundamentally impair the
u
splash-proof)
measuring results. These include, e.g. the proximity of
devices that generate strong electric, magnetic or
electromagnetic fields, moisture, metal building ma-
terials, foil-laminated insulation materials or conduct-
ive wallpaper or tiles. Therefore, also refer to other in-
formation sources (e.g. construction plans) before
drilling, sawing or routing into walls, ceilings or floors.
Hold the measuring tool by the intended gripping sur-
u
face (5) only, so as not to influence the measurement.
Do not attach any stickers or labels to the sensor
u
area (7) on the rear of the measuring tool. Metal labels
in particular will affect measuring results.
Capacity
60−100 %
30−60 %
5−30 %
0−5 %
Do not wear gloves when taking measure-
ments and make sure that you are properly
earthed. If you are not properly earthed, the
identification of live wires may be impaired.
When taking measurements, avoid devices
that emit strong electric, magnetic or elec-
tromagnetic fields. If possible, deactivate all
tools whose radiation could interfere with the
1 609 92A 6V7 | (16.08.2021)
English | 11