STEP 3-INSTALLING THE CEILING ASSEMBLY
NOTICE
Make sure that you have properly matched the roof top air conditioner and interior ceiling assembly.Caution
before tightening bolts:
1.
The applicable thickness of vehicle roof ranges from 30mm~80mm.
2.
Before tightening bolts, screw in the four bolts manually and prohibit screwing forcibly.
3.
When screwing bolts, you can use automatic tool. Do not tighten one bolt completely and then tighten other
bolts, in order to prevent sticking of screw thread.
4.
The max torque for tightening ranges from 2.3Nm~2.5Nm.
24
The following step by step instructions must be performed in the following sequence to ensure proper installation.
1.
Carefully take the ceiling assembly out of the carton
(The remote control packed with the ceiling assembly).
2.
Remove the ceiling grille from the ceiling assembly.
3.
Before installing the outdoor unit of recre- ational
vehicle air conditioner on the vehicle's top,
preinstall the plate of air vent and foam (upper) on
the chassis of the outdoor unit with 4pc of screws
(25mm long) (See fig.5-1) .
4.
Then carry the outdoor unit to the vehicle's top
and align with the openings on the vehicle's top.
Use 2 sets of mounting plate assembly and 4
screw bolts to mount the outdoor unit (See fig. 5).
You must start (thread) themounting bolts by hand
to avoid cross-threading. DO NOT START THE
MOUNTING BOLTS WITH AN AIR GUN. The mounting
bolts should be tightened, process is completed when
the basepan gasket has been evenly compressed.
5.
Before installing the air duct assembly of the
indoor unit of recreational vehicle air conditioner,
assemble the foam assembly according to the
thickness of the vehicle's top. After simulated
installation,
use
an
appropriate
amount
sponge and foam assembly. Stick the sponge
and foam assembly with double faced adhesive
tape (prepared by user) (See fig.5-2, 5-3)..
6.
Install the foam assembly on the air duct assembly.
Use 4 screw bolts to fix the air duct assembly onto
the mounting plate. After connecting the outdoor
unit with indoor unit, check whether the foam
assembly has come loose (See fig.5).
of
25