18 English
Your power tool is doubly insulated in
compliance with EN 60745; there is
thus no need for an earth wire.
EN
The machine is radio and TV interference-free in
accordance with EN 55014-1 and interference-
proof in accordance with EN 55014-2.
Noise and Vibration Information
Noise levels
Measurement values determined according to EN
60 745.
The A-weighted noise level of the device is typical-
ly:
Sound pressure level (L
Sound power level (L
Measurement uncertainty K = 3 dB
The noise level can exceed 85 dB(A)
during operation.
Wear ear protection!
4. Operation
Before carrying out any work on the
machine, pull the mains plug.

Putting into operation

Observe correct main voltage!
Before putting into operation, check that the mains
voltage and frequency on the identification plate
match the details of your mains supply.
Connect mains cable module if necessary
Mains Cable
If the mains cable is damaged while
working, pull the mains plug immedi-
ately.
Fixed power supply
Fixed power supply
Damaged mains cables must not be used. They
must be replaced immediately by an expert tech-
nician.
FME-EN / 1101
)
78 dB(A)
pA
)
89 dB(A)
wA
Mains cable module
Mains cable module with Patent
Quick Interlock.
Connect the mains cable module 7 to the handle.
The plug must snap in.
Use the mains cable module 7 only for Kress elec-
tric tools. Do not attempt to operate other ma-
chines with the module.
Damaged mains cable modules must not be used.
They must be replaced by a new Kress mains ca-
ble module immediately.
Push the two unlocking buttons 4 and remove the
mains cable module 7 from the handle.
Use only an original Kress mains cable module.

Additional function

Continuous electronic control (Option)
The continuous electronic control
keeps the speed almost constant
under no-load and under load and
ensures uniform performance.
Electronic control (Option)
In the event of overload or overheat-
ing during continuous operation, the
speed is automatically reduced until
the machine has cooled sufficiently.
Soft starter
The starting current limitation reduces the starting
current. The motor revs up slowly until it reaches
the preselected rotational speed. This can extend
the service life of the machine.
Electronic overload protection
With a load that is too high, which therefore im-
plies a risk to the motor, the rotational speed of the
milling motor is reduced by the integrated monitor-
ing of the motor. The machine must be released
(preferably remove it a short distance from the
workpiece) to ensure that you can have full capac-
ity again.