Putting Into Operation; Mains Cable - KRESS 1050 FME-1 Manual Original

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 46
40974_BA_FME_1603.book Seite 19 Mittwoch, 2. März 2016 5:51 17
Operation
Noise and Vibration Information
Noise levels
Measurement values determined according to
EN 60 745.
The A-weighted noise level of the device is typically:
Sound pressure level (L
pA
Sound power level (L
)
wA
Measurement uncertainty K = 3 dB
The noise level can exceed 85 dB(A)
during operation.
Wear ear protection!
Vibration
Triaxial vibration emission level determined in
accordance with EN 60745.
Milling a
h
Measurement uncertainty K
The vibration emission level given in
this information sheet has been
measured in accordance with a
standardised test given in EN 60745
and may be used to compare one
tool with another.
The vibration emission level will vary because of
the ways in which a power tool can be used and
may increase above the level given in this infor-
mation sheet. This could lead to underestimation
of vibration when the tool is used regularly in such
a manner.
Note: To be accurate, an estimation of the level of
exposure to vibration experienced during a given
period of work should also take into account the
times when the tool is switched off and when it is
running but not actually when doing the job.
This may significantly reduce the exposure level
over the total working period.
Identify additional safety measures to protect the
operator from the effects of vibration such as:
maintain the tool and accessories, keep the hands
warm, organisation of work patterns.
)
78 dB(A)
89 dB(A)
m/s²
5,0
m/s²
1,5
4. Operation
Before carrying out any work on the
machine, pull the mains plug.

Putting into operation

Observe correct main voltage!
Before putting into operation, check that the mains
voltage and frequency on the identification plate
match the details of your mains supply.
 Connect mains cable module if necessary

Mains Cable

If the mains cable is damaged while
working, pull the mains plug immedi-
ately.
Fixed power supply
Fixed power supply
Damaged mains cables must not be used. They
must be replaced immediately by an expert techni-
cian.
Mains cable module
Mains cable module with Patent Quick
Interlock.
Connect the mains cable module 7 to the handle.
The plug must snap in.
Use the mains cable module 7 only for Kress electric
tools. Do not attempt to operate other machines
with the module.
Damaged mains cable modules must not be used.
They must be replaced by a new Kress mains
cable module immediately.
Push the two unlocking buttons 4 and remove the
mains cable module 7 from the handle.
Use only an original Kress mains cable module.
English 19
EN
FME-EN / 1603
Tabla de contenido
loading

Tabla de contenido