6 946 25
Multi-outlet with repeater and WIFI access point
USB
5 V - 2400 mA
Wifi
RESET
button
Configuration of WIFI repeater function
1 - Connect the multi-outlet to a mains socket and press the main ON/OFF switch to turn it on.
2 - Press and hold the RESET button (6 to 10 seconds).
3 - Open the wireless configuration utility on your terminal (computer, tablet, phone),
select the name of the multi-outlet network Legrand_WIFI_Vx_xxxxxx and
connect to this network.
4 -
4 x 2 P+E with protective shutters
16 A - 230 V~ - 50 Hz
10/100 Mbps Ethernet switch
WiFi 2.4 GHz - IEE 802.11 b/g/n
2 x RJ45 ports (1 IN, 1 OUT)
•
Uc: 250 V - 50 Hz
•
Uoc: 4 kV
•
Icc: 3 kA
•
Up: 1 kV
•
Type 1 or 3
LED status
Static orange
RJ45
Flashing orange
Off
Open your internet browser and enter the address 192.168.16.1
then click Enter
Enter the default password: admin
Enter the default password: admin
Then click Enter
Consumption in stand-by mode: 1.65 W
Max. power: 3500 W
Main ON/OFF switch
Cable: 2 m
Built-in surge protector
Without surge protection
With surge protection
Up = 1 kV
Power on
Variable Ethernet traffic speed between 10 and 100 Mbps
Power off
Meaning
Currently connected to:
Internet access
Wireless network connection
Legrand_Wi _V1_A430EC Connected
Network 1
RR04DSI
RR05DSI
Guest
Other network