DESCRIPTION
Once plugged to 10000306-039 this key permits the control of sunlinds awings or similar loads, via Basic Set Commands and
Multilevel Start and Stop Level Change Commands.
KEYPAD USE & FEEDBACKS
EVENT
KEYPAD
DEVICE
FEEDBACK
ACTION
ESTATUS
LEDS
- OFF (Reference setting point 1
No pressed
and 12)
- Key not associated with a Z-Wave
network: intermittent of 2sec.
- Error: intermittent of 0.1sec.
Activate touch
Touch detected
Not Associated
Central LED blinks ntermittent of
area
0.1sec. for 5 seconds
Associated to 1 Simon
If associated Sunblind is going UP: UP
device
LED blinks for 5sec.
If associated Sunblind is going
DOWN: DOWN LED blinks for 5sec.
Associated to 1 non
UP and DOWN LEDs light up 5
Simon device
seconds (sunblind movement is
unknown).
Associated to n>1 devices
UP and DOWN LEDs light up 5 se-
conds (sunblinds stopped since last
key activation).
Press key
Short press (t<2s) in
Sunblind action is known
UP and DOWN LEDs light up for
UP zone
and it is going UP.
5sec.
Sunblind action is known
UP LED blinks until associated
and it is stopped.
sunblind stops
Short press (t<2s) in
Sunblind action is known
UP and DOWN LEDs light up for
DOWN zone
and it is going UP.
5sec.
Sunblind action is known
DOWN LED blinks until associated
and it is stopped.
sunblind stops
Short press (t<2s) in
undetermined zone
Sin Not Associated
Central LED blinks for 5 seconds
Add/Remove
Long press 2s<t<10s
Central LED blinks after key release
from Z-Wave
Associate/
Long press
Central LED blinks slow for
Disassociate
2s<t<10s
Association Time (15 seconds).
Reset default
Long press t>30s
Main LED light up for 2.5 sec.
* Some of the functions can be changed depending on the configuration parameters.
** Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Z-WAVE COMPLIANCE
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers
and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase
reliability of the network.
Z-WAVE SPECIFICATIONS
SUPPORTED COMMAND CLASSES
Z-WAVE DEVICE SPECIFICATION
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
Device Type
WALL_CONTROLLER
Generic Device Type
GENERIC_TYPE_WALL_CONTROLLER
COMMAND_CLASS_VERSION_V2
Specific Device Type
SPECIFIC_TYPE_BASIC_WALL_CONTROLLER
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
Role Type
ROLE_TYPE_SLAVE_ALWAYS_ON
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_MULTILEVEL SWITCH_V3
CONTROLLER COMMAND CLASSES
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_MULTILEVEL SWITCH_V3
COMMAND_CLASS_CONFIGURATION_V2
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_CONFIGURATION_V2
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
COMMAND_CLASS_CENTRAL_SCENE_V2
COMMAND_CLASS_CENTRAL_SCENE_V2
Groups
Group 1 (Lifeline) -> Name "LIFELIFE"
Max. devices in Group
3
Automatic reports
After reset the Z-Wave module, a DEVICE-RESET-LOCALLY-NOTIFICATION is sent.
Pressing without having nodes associated with the control group is notified by a CENTRAL_SCENE_NOTIFICATION
DEVICE
Groups
Group 2 (Control) -> Name "CONTROL"
Max. devices in Group
20
ACTUATION
Actions
During Association process or then Association Set is received
CC Manufacturer Specific, Manufacturer Specific Get: (to discover manufacturer)
CC Association, Association Set: (review param 28 to know more about this command use).
CC Association, Association Remove: (review param 28 to know more about this command use).
CC Configuration, Configuration Set Param 1, 0xFF -> when association process is started this Configuration Set
will be sent to all Simon devices in group to identify devices involved in this group.
CC Configuration, Configuration Set Param 1, 0x00 -> when association process is finished this Configuration Set
will be sent to all Simon devices in group to identify devices involved in this group.
Key consults the associated control via
(Configuration Get Param 21). While
CC Configuration, Configuration Set Param 1, 0xFF ->Sent when a new device is associated thought association
controlled device report is not received
process and this device is a Simon device.
the key will set the controlled device on
CC Configuration, Configuration Set Param 1, 0x00 -> Sent when a device is disassociated thought association
Unknown state.
process and this device is a Simon device.
Key consults the associated control via
When Touch area is detected o key is pressed without touch area detection:
(Basic Get). While controlled device re-
CC Configuration, Configuration Get, Param 21 -> Sent if param 28 value is 0x00, there is only 1 device is associa-
port is not received the key will set the
controlled device on Unknown state.
ted and it is a Simon device. Used to know the associated device state.
The Key decides the Control state
CC Basic, Basic Get -> Sent if param 28 value is 0x00, there is only 1 device is associated and it is not a Simon
according its last sent value.
device. Used to know the associated device state.
When pressed and later than knowing the controlled devices state:
Multilevel Stop Level Change is sent to
COMMAND_CLASS_BASIC_SET
associated device/s
It is sent to the associated nodes after a push to change its state:
Multilevel Start Level Change UP with
Value: 0xFF to enable / 0x00 to disable
default time y and sunblind movement
It is relayed to the associated nodes when Z-Wave receives a BASIC_SET.
is polled through Basic Get each 5seg.
COMMAND_CLASS_MULTILEVEL_SET
Multilevel Stop Level Change is sent to
COMMAND_CLASS_MULTILEVEL_START_LEVEL_CHANGE
associated device/s
COMMAND_CLASS_MULTILEVEL_STOP_LEVEL_CHANGE
Multilevel Start Level Change
It is sent to the associated nodes after a push to change its state:
DOWN with default time y and sun-
It is relayed to the associated nodes upon receipt by Z-Wave.
blind movement is polled through
Basic Get each 5seg.
If controled device status is not asked
yet, Key will consult the its status and:
-If sunblind is moving -> Sends Stop
Level Change.
- If sunblind is stopped with level higher
NAME
than 78% Multilevel Start Level Change
1
Association LED
DOWN is sent and sunblind movement
is polled through Basic Get each 5seg.
- If sunblind is stopped with level higher
12
Behavior of LED in Repose
than 78% Multilevel Start Level Change
0xUP is sent and sunblind movement
13
Lock Input
is polled through Basic Get each 5seg.
15
Reset Default (Write Only)
Device sends a Node Info to be added or
removed into or from a Z-Wave network
Each time a Node Info is received
18
Manual association lock
from a device of the same network,
the key will associate this device to
its control Group (if it wasn't alre-
19
Press Action
ady in) or Disassociate(if device was
in). Assocaition Time will be resto-
red and if the associated device is
a Simon's device Central LED will
be turned ON during Association
Process.
Reset to default state.
20
Identify (Write only)
21
Device State (Read Only)
25
OFF VALUE
26
ON VALUE
27
Consult on Touch detection
28
Consult on Touch detection
29
Enable automatic reporting CENTRAL_
SCENE
All These configurations are not restored to default when device is removed from network.
COMMAND_CLASS_DEVICE_RESET_LOCALLY -> DEVICE_RESET_LOCALLY_NOTIFICATION will be sent to inform controller that node has
been removed from network, but the device will keep the current configurations.
To restore the configurations values, please perform one of these actions:
-Use Command CONFIGURATION SET with default bit to 1 for each configuration parameter.
-Perform Reset Default Action via keypad pressing or Command Reset Default.
ASSOCIATION GROUPS
CONFIGURATION
SIZE
VALUE
1
0x00 -> Turns the LED OFF (value default)
0xFF -> Turns the LED ON
1
0x00 -> LED OFF (value Default)
0xFF -> UP and DOWN LED on at 20% of maximum level
1
0x00 -> Unlock the direct control of load. (value Default)
0xFF -> Lock the direct control of load.
2
0x9867 -> Parameters, Groups, and Z-Wave status are restored to default.
0x4312-> Parameters, except Lock long press are restored to default.
1
0x00 -->Unblocked (default value)
0xFF --> Blocked
1
0 -> (Default value) Pressing t <2sec switches between the last power on and off (depending on
the status of the associated control) by sending a Basic Set to 0x00 or 0xFF to the associated
nodes.
1 -> Pressing t <2sec always activates those associated with the last power on by sending a Basic
Set to 0xFF
2 -> Pressing t <2sec always deactivates associates by sending a Basic Set to 0x00
3 -> Pressing t <2sec on the left side sends a Basic Set to 0x00 and the DOWN 5s LED lights up.
By pressing t <2sec on the right side. A Basic Set is sent to 0xFF and the UP 5s led is lit.
4 -> Pressing 0sec <t <2sec always activates the associated nodes by sending a Basic Set to 0xFF
Pressing 2sec <t <10sec always turns off the associated nodes by sending a Basic Set to 0x00
* Does not send Node Info nor does the central LED flash.
6 -> Pressing t <2sec on the left side sends a Basic Set with VALUE OFF or 0x00 (depending on
whether an OFF VALUE has been set)
* If VALUE OFF is set, the DOWN LED lights up for 5sec. Otherwise the UP and DOWN
LEDs will be activated briefly.
Pressing t <2sec on the dcho side sends a Basic Set to VALUE ON or 0x00 (depending on
whether an ON VALUE has been set)
* If VALUE ON is set, the UP LED is lit for 5 seconds. Otherwise the UP and DOWN LEDs
will be activated briefly.
7 -> (value Default) The associated nodes are controlled as described in the USE table KEY-
BOARD AND ANSWERS
1
0xFF -> the central LED blinks for 5 seconds in order to identify the device.
2
B0 --> Blind state
0x00 --> Stop
0x01 --> Going up
0x02 --> Going down
B1 --> % Height of the blind
% illumination level of the associated node
1
0x00-0x63 (max) Set the value of OFF
1
0x00-0x63 (max) Set the value of ON
1
0x00 -> Long press works as described previously.(value Default)
0xFF -> Long press of 2s<t<10s don't sends the Node Info
Long press of t>30s Parameters, except Lock long press are restored to default.and
device sends a Node Info.
1
0x00 ->(if there is 1 Associated device) when Touch is detected, controlled device state
will be consult. (value Default)
0xFF-> (if there is 1 Associated device) when Touch is detected, controlled device state
is not consulted.
When Assocaited devices number is changed and before or after association there is 1
Simon's device, the key will perform an Association Set o Remove to be informed about
controlled device state or reduce the traffic on Z-Wave network.
When the param value is 0xFF and one device is associated:
-Si associated devices goes from 0 to 1 or from 2 to 1 and it is a Simon device, the Key
will send an Association Set to the Device group 2. (If it is not a Simon's device please
associate them manually)
-If associated devices goes from 1 to 0 or from 1 to 2 and the first device is a Simon device,
The key Sends an Association Remove to group 2 of the first device. (If it is not a Simon's
device please disassociate them manually)
1
0x00 -> Enables CC Central Scene Notification when there are no nodes associated with
the control group and Inhibits error signaling by pressing t <2s if there are no associated nodes.
0xFF -> Enables error signaling by pressing t <2s if there are no associated nodes.
SIMON, S.A.U. Diputación, 390-392 / 08013 Barcelona
www.simonelectric.com