geberit ECO 203 Operación Manual página 30

Ocultar thumbs Ver también para ECO 203:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 84
EN
Rectifying malfunctions before the pressing procedure
Fault
Pressing tool cannot
be activated from idle
state; none of the
LEDs light up
Green LED flashes
Rectifying malfunctions during the pressing procedure
Fault
Green LED flashes and
roller drive moves
back to its starting
position
Red LED flashes
30
Cause
Mains cable or
mains plug is
defective
Retaining pin is
incorrectly
pushed in or is not
pushed in until the
stop position is
reached
Cause
Retaining pin has
come loose
Start button was
released too soon
Release button
was pressed or
pressing tool was
not in starting
position
Pressing tool is
outside of the
operating
temperature
Action
Mains cable or mains plug is
defective
Examine the retaining pin for
damage
Push the retaining pin in until the
stop position is reached
Action
Examine the retaining pin for
damage
Push the retaining pin in until the
stop position is reached: green LED
lights up
Examine the pressfitting for
tightness and repeat the pressing
operation if necessary
Press and hold release button: roller
drive moves to its starting position
Repeat the pressing operation:
press the start button for approx.
2 seconds
Release start button
Press and hold release button: roller
drive moves to its starting position
Repeat the pressing operation:
press the start button for approx.
2 seconds
Bring the pressing tool into a
warmer environment or leave it to
cool down
Bring the pressing tool to the
required operating temperature by
performing multiple blank pressing
operations (pressing operations
without a fitting)
B1279-001 © 02-2016
966.996.00.0 (00)
Tabla de contenido
loading