Technical Data
• Max. flow
- Spout
- Handshower
Installation
Install thermostat handel, see fold-out page I Fig. [1].
1. Remove clip (Y1).
2. Detach stop ring (Y).
3. Turn stop ring (Y) and install with the marking (Y2) pointing
to the front.
4. Install clip (Y1)
5. Fit sleeve (A).
6. Grease seal (B) with special grease supplied.
7. Attach escutcheon (C).
8. Install thermostat handle (D), see detail and screw in
screw (E).
9. Fit decorative ring (F).
10.Screw in cap (G).
The thermostat is adjusted at the factory. If, due to
installation conditions, re-adjustment is necessary, please
see Adjusting thermostat.
Install shut off handel, see fold-out page I Fig. [1].
1. Remove snap insert (H) and unscrew spindel (J).
2. Attach escutcheon (K).
3. Reinstall spindle (J), snap insert (H) and secure with
screw (L).
4. Fit decorative ring (M) on shut-off handle (N).
5. Install shut-off handle (N) complete, see detail.
6. Screw in cap (O).
Install handspray, see fold-out page I Figs. [2] and [3].
1. Mount shower hose (P) with shower connection hose (P1)
from rough installation, see Fig. [2].
2. Insert shower hose (P) through escutcheon (Q) and fit
escutcheon (Q).
3. Insert shower hose (P) through guide with integrated shower
seal (R) and screw guide (R) in hose guide (R1).
4. Screw coupling piece (S) onto shower hose (P).
5. Fit handspray (T) to coupling piece (S), see Fig. [3].
When using the handspray (T), it must be ensured that spray
water does not penetrate the guide (R).
Install spout, see fold-out page I Fig. [3].
1. Attach spout (U) to shank (U1), insert set screw (U2) using
a 4mm allen wrench and screw on cap (U3).
1
English
Adjusting thermostats
• Before putting into service
• Following all maintenance operations on the thermostatic
approx. 29 L/min or 7.7 gpm
cartridge
max. 9.5 L/min or 2.5 gpm
- Open the shut-off valve via shut-off handle (N) and check
the temperature of the water using a thermometer, see
Fig. [4].
- Turn regulating nut (V) clockwise or counter-clockwise until
the water temperature has reached 100 °F.
- Attach temperature control handle (D), see detail and screw
in screw (E).
- Fit decorative ring (F).
- Screw in cap (G).
Temperature limitation
The safety stop limits the temperature range to 100 °F.
If a higher temperature is desired, the 100 °F stop can be
overridden by pressing the button (D1).
Prevention of frost damage
When the domestic water system is drained, thermostats must
be drained separately, since non-return valves are installed in
the hot and cold water connections.
The complete thermostat assemblies and non-return valves
must be removed.
Maintenance
Maintenance, see fold-out page I Figs. [5] and [6] and fold-out
page II Figs. [7] to [11].
Inspect and clean all parts, replace if necessary and apply
special grease (order no. 18 012).
Shut-off hot and cold water supply; also possible by
closing the isolating valves, see fold-out page I, Figs. [5]
and [6].
1. Unscrew cap (G), see fold-out page I, Fig. [5].
2. Loosen screw (E) and detach temperature control
handle (D) complete.
3. Remove escutcheon (C).
4. Remove mounting set (C1) and remove escutcheon
mounting base (C2).
5. By loosening bolts (W), the THM unit can be moved to the
right and to the left, see Fig. [6].
6. Close both isolating valves (X) using an 8mm allen wrench.