Dishwasher machine with 1 solenoid valve
Connect only the top-up cable (F) to the solenoid valve of initial charge/rinse.
The pump works for the first 30 seconds at the top-up time settings by the trimmer (B) and then is the signal
is still active the pump will work at the load dosing time.
In the model TEC-2TT the initial fill dosing time is equal to the difference between the time set
by the trimmer (B) and that set by the trimmer (H).
Example:
T
= 70 seconds
CHARGE
Dishwasher machine with 2 solenoid valves
Connect the load cable (E) to the solenoid valve of initial charge.
Connect the top-up cable (F) to the solenoid valve of rinse.
1)Periodically check the chemical tank level to avoid the pump operates without liquid.
2)Check the suction and delivery hoses in which the presence of some impurity could cause a damage of the
pump head hose and a low flow in the same time.
3)Check regularly the functioning of the pump especially when it doses aggressive chemicals and the state
of the filter whose clogging can decrease the flow.
Hose of the pump head
Suction and Delivery hose
Foot Filter
Injection nipple
-
SUCTION HOSE 2m
-
DELIVERY HOSE 2m
-
FOOT FILTER
-
INJECTION VALVE
Note on environmental protection
After the implementation of the European Directive 2002/96/EU in the national legal system, the following applies:
Electrical and electronic devices may not be disposed of with domestic waste. Consumers are obliged by lak to return
electrical and electronic devices at the end of their service lives to the public collecting points set up for this purpose.
Detalis to this are defined by the national law of the respective country. This symbol on the product, the instruction
manual or the package indicates that the product is subject to these regulations. By recycling, reusing the material or
other forms of utilising old devices, you are making an important contribution to protecting our environment.
ADSP7000471 – 17/04/2014
PUMP FUNCTIONING
T
= 15 seconds => T
TOP-UP
MAINTENANCE
MATERIALS IN CONTACT WITH THE CHEMICALS
Santoprene® (upon request Silicone® and Tygon)
PVC (delivery PE for Silicone® e Tygon versions)
Polypropylene
Polypropylene (AISI for Silicone® e Tygon versions)

ACCESSORIES KIT

= 70 - 15 = 55 seconds