Minebea Intec Combics Ex Serie Instrucciones De Instalación página 21

Puerto de salida para interfaz
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

CAIXS2
4b) 4a)
Data
Adapter
Board
CAIXS2
4b) 4a)
Data
Adapter
Board
up to 8 devices in
the hazardous area
FC/FCA/IS......-.X...
3)
FCT01-X..
SIWXS.../ ISX...
with RS-485 data
output port
CIXS3
LV2
If necessary, connect final
UNICOM
terminal with 470 ohms /0.6W
(pin 2/3 or J/K)
Important note:
Max. voltage V
of any electrical apparatus connected to the Zener
m
barrier must not exceed 250V. Zener voltage V
Hazardous area
CAIXS2
Data
Adapter
Board
YAS04CIS**
Data adapter board
TxD+
TxD-
RxD+
RxD-
DTR+
DTR-
CTS+
CTS-
Signal_GND
Important note:
Max. voltage V
of any electrical apparatus
m
connected to the Zener barrier must not exceed
250V. Zener voltage V
is 12.6V.
z
Hazardous area
Non-hazardous area
2)
4b) 4a)
is 12.6V.
z
Non-hazardous area
up to 1000m
**
4
green
yellow
3
12
pink
gray
6
5
violet
black
7
11
red
blue
10
brown, white
1,2
**: not incl. in equipment
supplied withYDI05-ZV1
YDI05-Z
1)
with Option
A24,
M50
M
14-contact female
connector of data output
port of FC/FCA/IS-.X.. /
J
FCT....-X... / SIWXS... /
ISX...
K
CAIXS2
CIXS3
Data
UNICOM
adapter
LV2
board
RxD-TxD-P (A)
2
2
RxD-TxD-N (B)
3
1
Signal_GND
1
3,4
1: Total length up to 1000m (follow technical data on the EC type
examination certificate); cable is not included in the standard equipment
supplied; YCC485-X (light-blue cable); please indicate length)
2: Junction box 72583
3: 14-contact male connector 69Y03166
4: Optional: separable connection 6906924 (a) and 6906925 (b)
CAIXS2 /
RS-485 Wiring
External Connections and
2013-08-08
Klausgrete
LV3
YDI05-Z
Interface
converter
with Options
M53, A25, M55
see also page 9
LV1
1
6
LV3
LV1
12-contact
9
or
RxD+
4
10
RxD-
7
TxD+
1
8
TxD-
5
CTS+
3
6
CTS-
3
DTR+
2
4
DTR-
5
1, 2
CAIXS2 /
RS-422 (EX) - RS-232 (Non-EX) Connection
External Connections and
2013-08-08
Klausgrete
Data transfer
12-contact male
connector
69QC0010
PC or SPS with RS-
485 data output
port
E
Option M50:
12-contact
female
connector
on YDI01-Z
14-
YDI05-Z
12-contact
contact LV2
J
1
C
(white)
K
4
B
(yellow)
M
1 (LV1)
E
(grey)
Sheet
Data Transfer
of
66015-741-50
Rev. 00
DC power supply
12V DC (min) ...
30V DC (max)
RS-232 connection
see also pages 4 and 5
B
TxD
C
RxD
D
DTR
H
CTS
E
Signal_GND
Sheet
Data Transfer
of
66015-741-50
Rev. 00
Betriebsanleitung Combics CAIXS2
YDO07-X
C
B
7
9
8
9
131
21
Tabla de contenido
loading

Este manual también es adecuado para:

Ydo07-x

Tabla de contenido