Device elements
1 Electrodes
2 Suction support
3 Suction hose
4 Hose hook
5 Crevice nozzle
6 Air outlet, working air
7 Suction head
8 Suction head lock
9 Recessed grip
10 Dirt receptacle
11 Steering roller
12 Handle
13 Air inlet, motor cooling air
14 Floor nozzle
15 Suction tube
16 Stop for tool box
17 Rubber sleeve, screwable
18 Fixing eyelet
19 Filter cover
20 Carrying handle
21 Suction force regulator (continuous)
22 Tool adapter
23 Rotary switch for suction output (min-
max)
24 Rotating knob
25 Socket
26 Floor nozzle holder
27 Holder for suction pipe
28 Bender
29 Power cord
30 Holder for bender
31 Filter frame
32 Flat fold filter (PES)
33 Filter dedusting
34 Nameplate
Symbols on the machine
WARNING: This appliance contains harm-
ful dust. The emptying and maintenance,
including the removal of the dust bag, may
only be executed by trained personnel
wearing suitable protection equipment. Do
not switch on until the complete filter sys-
tem has been installed.
Safety instructions
DANGER
– When the outgoing air is carried back
into the room, a sufficient ventilation
rate L in the room must be ensured. To
comply with the required limit values the
carried back volume flow must be 50%
of the fresh air volume flow (room vol-
ume V
x ventilation rate L
R
mum. Without a specific ventilation sys-
tem the following applies: L
– Only persons trained in the use of the
machine and the handling of substanc-
es for which the machine is to be used
including training in the safe disposal of
the sucked-in material may use the ma-
chine.
– This appliance contains harmful dust.
Evacuation and maintenance work, in-
cluding the disposal of the dust collec-
tion containers, may only be performed
by specialists who wear the appropriate
protective equipment.
– Do not use the appliance without the
complete filtering system.
– 2
EN
Flat fold filter (PES)
Order No.
6.904-360.0
Flat fold filter (cellulose)
Order No.
6.904-367.0
Flat fold filter (PTFE)
Order No.
6.907-455.0
W
W
) at maxi-
=1h
.
–1
17