Application Of Corrected Data To The Data Plate; Burner Security Lock; Commissioning - KIWA TECHNOLOGY GOURMET 511 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 80

APPLICATION OF CORRECTED DATA TO THE DATA PLATE

After the transformation it is mandatory to apply the sticky plate with the correct data on the data
plate on the left side of the unit.

BURNER SECURITY LOCK

During the first start (due to presence of air in the circuit), after the transformation to a different
gas type, or due to technical problems, the burner can be locked (after the third failed attempt to
flame ignition). This block is signaled by the red light
(page 17). To unlock the burner press the button on the back of the dashboard under the lock
light.(figure below)
Note During this operation, the oven door must remain closed
If the block is repeated with some frequency contact the technical Support

COMMISSIONING

Before starting the equipment for the first time, check that:
all connections have been made correctly
the film has been completely removed
the pan support guides have been assembled correctly;
the main electrical switch upstream is activated
the upstream gas shut-off valve is open;
the water tap is open
Easy Series Ovens – Page 34