Gas Transformation - KIWA TECHNOLOGY GOURMET 511 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 80

GAS TRANSFORMATION

ATTENTION
The work that is necessary for the transformation can only be performed by service
personnel authorized by the manufacturer or by the manufacturer itself.
For transformation to another type of gas, for example from G20 to G31, a gas adjustment baffle
must be positioned and the gas must be regulated.
Systems with G31 gas will have a baffle. For a transformation that is opposite to what was
described above, the baffle will be removed.
ATTENTION
Before starting each transformation, close the upstream shut-off valve and switch off
the power
For the positioning of the baffle proceed as follows:
Remove the filler panel on the bottom of
the unit.
Identify the burner supply unit inside the
component compartment.
Once connection is complete, check the seals with a leak detection spray that does not cause
corrosion. It is absolutely prohibited to use open flames!
S
e
parate the gas valve unit (C) from air/gas mixer
(B). Place the baffle (A) in the special slot located
on the fitting of the gas valve unit (C). Reconnect
the gas valve unit (C), provided with the baffle, to
the air-gas mixer (A).
To remove the baffle, proceed in reverse
Easy Series Ovens – Page 33
Tabla de contenido
loading

Este manual también es adecuado para:

Gourmet 1011Bistrot 456Bistrot 665Bistrot 1065Easy 6Easy 10

Tabla de contenido