Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
DSC
EXAMPLE OF CONNECTION WITH CONTROL UNIT WITH FRAME INPUT
FIG. 2
SEE BOARD
RESET
SERIES CONNECTION OF TWO OR MORE CONDUCTIVE EDGES
FIG. 3
2
1
DIAGNOSTICS
DCS80 is fitted with two LEDs (CH1, CH2) which indicate the relay status. During normal operation, these
LEDs are on. When they go off it means that a fault has occurred i.e. the sensing device has intervened or it
is not functioning properly. Therefore, when the LEDs are on, the corresponding outputs will be active,
while when they are off, the outputs will be inactive.

BOARD RESET

JP1
Terminal
Function
AUTOMATIC
6
5
A B C
6
5
A B C
P1
DOUBLE MODE TEST
1) TEST with NO clean contact
• Connect the TEST between terminals 3 and 4.
• With contact open: board running
• With contact closed: board in TEST phase
SAFETY
DEVICE
Description
After the safety device has intervened and reset, the board automatically reactivates
RESET
After the safety device has intervened and reset, the board remains locked until it is manually
MANUAL
reset by pressing the button P1
RESET
SEE BOARD RESET
COM
+SAFETY
SAF.DEV.
COM
SAFETY
DEVICE
9
UK
8K2
SAFETY
DEVICE