b
(mm)
a
Maximum snowfall height
b
EKFT008D option kit
c
Anti-vibration rubber (field supply)
4.2.2
To install the outdoor unit
CAUTION
Do NOT remove the protective cardboard before the unit is
installed properly.
1 Lift the outdoor unit as described in
outdoor unit" on
page 4.
2 Install the outdoor unit as follows:
▪ (1) Put the unit into position (using the sling to the left and
the handle to the right).
▪ (2) Remove the sling (by pulling 1 side of the sling).
▪ (3) Fix the unit.
ERGA04~08DAV3
Daikin Altherma – Low temperature split
4P489913-1B – 2017.10
4×
c
3 Remove the protective cardboard and instruction sheet.
a
4.2.3
Make sure that condensation water can be evacuated properly.
▪ Drain pan. You can use the drain pan option (EKDP008D) to
"2.1.1 To handle the
a
1
a
Air outlet
NOTICE
Properly align the unit. Make sure the backside of the unit
does NOT protrude.
a
Protective cardboard
b
Instruction sheet
To provide drainage
NOTICE
If the drain holes of the outdoor unit are blocked up,
provide space of at least 300 mm below the outdoor unit.
gather the drain water. For the complete installation instructions,
see the installation manual of the drain pan. In short, the drain pan
is installed as follows:
a
Drain pan
b
U-beams
4 Installation
2
a
3
2×
b
a
b
Installation manual
7