Bosch 8 707 207 277 0 Instrucciones De Montaje página 10

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 5
6720608089-0707 (Jumper2).fm Page 10 Monday, July 16, 2007 2:14 PM
Gas regulation
B Dismantle both injectors groups and replace
them.
B Reassemble the burner.
B Ensure there are no gas leaks.
B Open electronic cover.
B Set the jumper settings according to table 2.
Fig. 5
Jumper (natural gas configuration)
B Take note of the new gas type in the appliance
type plate.
JP6
Gas type
With jumper
Natural Gas
Without
LPG
Table 2 Gas type jumper configuration
1.5
Temperature range selection
Appliance temperature range is set to 35°C -
60°C. Placing jumper JP7, temperature range
changes to 38°C - 50°C.
10
Fig. 6
Temperature range set
1.6
Start-up delay
Placing jumper JP2, the appliance will only ignite
after 3 seconds of start-up water flow detection.
Fig. 7
Start-up delay
6 720 608 089
Tabla de contenido
loading

Este manual también es adecuado para:

8 707 207 308 08 707 207 309 08 707 207 310 08 707 207 311 08 707 207 313 0

Tabla de contenido