Installation Requirements; Tools And Parts; Location Requirements - Kitchen Aid KUWR204EPA Manual De Uso

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Tools and Parts

Tools Needed
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Cordless drill
¹⁄₁₆" and ³⁄₈" brad point
doweling drill bit
Phillips screwdriver
Rotary tool
Parts Needed
Custom Overlay Frame—See "Overlay Frame—Rear
View."
Parts Supplied
Flat-head screws (TRUSS M4x34 Tapping) (8)

Location Requirements

WARNING
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from wine cellar.
Failure to do so can result in death, explosion, or fire.
To ensure proper ventilation for your wine cellar, allow for a ¹⁄₄"
(6.35 mm) space on each side and at the top. When installing
your wine cellar next to a fixed wall, leave 2¹⁄₂" (6.35 cm)
minimum clearance on the hinge side to allow for the door to
swing open.
4 4

INSTALLATION REQUIREMENTS

Scissors
C-clamp
Masking tape
Tape measure
Petroleum jelly
NOTE: It is recommended that you do not install the wine cellar
near an oven, radiator, or other heat source. Do not install in a
location where the temperature will fall below 55°F (13°C). For
best performance, do not install the wine cellar behind a cabinet
door or block the base grille.
¹⁄₄
" (6.35 mm)
Opening Dimensions
Height dimensions are shown with the leveling legs extended
to the minimum height.
NOTE: When leveling legs are fully extended, add ⁵⁄₈" (15 mm)
to the height dimensions.
If the floor of the opening is not level with the kitchen floor,
shim the opening to make it level with the kitchen floor.
³⁄₄
14
"
(37.5 cm)
A
¹⁄₂
"
(1.3 cm)
24"
(60.96 cm)
min.
24" (60.96 cm) min.
Critical Dimensions:
³⁄₄
A. 14
" (37.5 cm) utility opening
B. 24" (60.96 cm) minimum opening width
¹⁄₂
2
" (6.35 cm)
³⁄₈
34
" (87.3 cm) min.
35" (88.9 cm) max.
B