Fault Clearance - Techem compact V Manual De Operación

Ocultar thumbs Ver también para compact V:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 53

Fault clearance

Before you look for a fault on the heat meter itself, please check the following items:
Is the heating on? – Is the circulation pump running?
Are the shut-off devices fully open?
Is the pipe free (possibly clean the strainer)?
Is the dimensioning okay?
Display levels
The heat meter has two display levels - the reading level and the service level:
A long press of the button switches between the two display levels.
!
In the device number display, the number next to the display identifier is the first
digit of the device number.
Key for
2
1
Readout level
1.1
Cumulated energy since
commissioning
1.2
Display test "everything on"
1.3
Display test "everything off"
1.4
Display test "UHF ON/OFF"
1.5
Due date value
1.6
Due date*
* The production date is displayed here before the first due date.
LT = long button press (> 3s)
KT = short button press (< 3s)
3
2
Service level
2.1
Current flow rate
2.1
Inlet temperature
2.3
Outlet temperature
2.4
Temperature difference
2.5
Current performance
2.6
Cumulated volume since
commissioning
2.7
Next due date
2.8
Device number
2.9
Firmware version number
2.10
Firmware check sum
9