//MAINTENANCE
Filter cleaning instructions
This mixer is provided with one/two stainless steel filter(s) preventing foreign particles to enter
the lines. If the water flow has decreased, this may be because the filter(s) is (are) clogged. The
filter(s) can be cleaned as follows:
1 –
Shut-off the water shut off valve (angle valve).
2 –
Disconnect the flexible pipe.
For mixer models
disconnect the red and the blue flexible pipes from the
back-checks and filter adapters and then disconnect the back-checks and filter adapters from
the hot and cold water supplies.
3 –
Remove the filter(s) and wash it (them) under running water.
4 –
Reassemble the parts. For Classic 1000 models, reassemble the parts by putting back the filter(s)
to the back-check and filter adapters.
5 –
Reconnect the flexible pipe(s) and restore the incoming water supply. For Classic 1000 models,
make sure that the filter adapters and the filters are installed between the flexible pipes and the
shut off valves (angle valves).
6 –
Make sure that there is no water leakage.
Care and cleaning of chrome and special finishes
Do not use steel wool or cleansing agents containing alcohol, acid, abrasives, or the like. Use
of any prohibited cleaning or maintenance products or substances could damage the surface of
the faucet.
For surface cleaning of faucet use only soap and water, then wipe dry with clean
cloth or towel. When cleaning bathroom tile, the faucets should be protected from any splattering
of harsh cleansers.
48//49