Assembly (see page 4)
Important! Do not use silicone containing acetic acid!
Important! The fitting must be installed, flushed and tested
after the valid norms.
The premounted filter insert must be used to ensure a nor-
mal flow of the shower and to prevent dirt from entering
through the pipes. Dirt entering can affect the function
and/or lead to damages to the shower. HansGrohe will
not be held liable for this type of damage. (see page 4).
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
Do not allow the streams of the shower touch sensitive
body parts (such as your eyes). An adequate distance
must be kept between the shower and you.
The hot and cold supplies must be of equal pressures.
Fault
- Insufficient water
- Mixer stiff
- Mixer dripping
- Instantaneous heater didn't work
English
Maintenance
The non return valves must be checked regularly according
to DIN EN 1717 in accordance with national or regional
regulations (at least once a year).
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Rate of flow by 0,3 MPa:
Tub outlet
Shower outlet
Spare parts (see page 3)
Operation (see page 5)
Cause
- Shower filter seal dirty
- Cartridge defective, calcified
- Cartridge defective
- Filters are dirty
approx. 18 l/min
approx. 16 l/min
Remedy
- Clean filter seal between shower
and hose
- Exchange cartridge
- Exchange cartridge
- Clean the filter / exchange filter
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 80° C
65°C