3
Guide the wires from the J-box and push them into the holes of the electrical disconnect plug, careful to match the corresponding wires already attached
to the electrical disconnect plug from the fixture. Push excess wire and wire connections back into electrical box. Note: Ground wires can either be
green or bare copper.
Position fixture over the mounting strap and tighten the long machine screw (CC) through the center hole of the wall plate into mounting strap. Restore
power to the electrical box and verify the light is functioning properly. If the light functions properly, fasten the silicone cap (EE) into the mounting screw
opening.
SENSOR ORIENTATION
CONTROL PANEL
FACING DOWN
The fixture cannot be used as a dusk-to-dawn light. The fixture has a built-in light sensor that prevents the motion
sensor from activating during daylight hours.
After the power is turned on, the fixture needs 15-20 seconds to
warm-up. The light will turn off after 15-20 seconds, then the light
will turn back on again going to the SetToGo preset of 50ft distance
and 3 minute light activation.
Light controls are set for 50ft distance and 3-minute light
activation. The distance and light activation time can be adjusted.
The TIMER control determines the length of
time the lights stay on. When the TIMER
control is set between 1 and 10, the light will
only come on during night time hours.
The greater the SENSITIVITY setting, the great the
chance for false activations by the (PIR) sensor.
The (PIR) sensor should be angled slightly downward
at all times. DO NOT exceed a ~45 degree angle
(Fig.1) to ensure the water will run off and not expose
the controls to splashing water.
DO NOT POSITION THE SENSOR WITH THE
CONTROLS FACING UPWARD.
Adjust the PIR
control panel to
desired location.
45°
MAX.
the PIR control
panel should
face downward
for easy access
USING THE (PIR) SENSOR & LIGHT ACTIVATION CONTROLS
MOTION SENSOR:
The light turns on when the motion sensor detects movement. Sensor detects motion up to 70ft. the
180-degree coverage of the motion sensor is measured side-to-side. The sensor is more effective
side-to-side, rather than motion coming straight at it (in-and-out). If the light does not turn on try
adjusting the sensor head. Sensor head can be adjusted either up or down, or left to right.
SET TIMER KNOB TO
anywhere from 1' to 10'
SETTING THE LIGHT ACTIVATION TIME:
Rotate the TIMER control knob clockwise to control the length of time the lights will remain on. The
time settings of 1 (1 min.), 5 (5 min.) and 10 (10 min.) are marked. However, the TIMER control
knob can be set anywhere from 1 minute up to 10 minutes. The time length can be adjusted up or
down.
SET TIMER KNOB TO
anywhere from 1' to 10'
SETTING THE MOTION DETECTION DISTANCE:
Rotate the SENSITIVITY control knob anywhere from "10Ft"to MAX.
(70 feet). When the SENSITIVITY control knob is turned to "10Ft",
the detection zone is very tight and compact, causing the detection
sensitivity to be very high. The reverse is true, when the
SENSITIVITY control knob is turned to "MAX." it
increases the detection zone exponentially.
45°
Perform a "walk by test" by walking across the
MAX.
motion detection field at the approximate
distance set on the SENSITIVITY control knob. IF THE TEST FAILS, try
adjusting the sensor head toward the detection zone. Sensor head can be
Fig. 1
adjusted either up or down, or left or right.
SET TIMER KNOB TO
anywhere from 1' to 10'
4
CC x1
EE x1
LIGHT ORIENTATION
SET SENSITIVITY KNOB TO
anywhere between 10ft and MAX.
SET SENSITIVITY KNOB TO
Any distance.
SET SENSITIVITY KNOB TO
10Ft to MAX (70 ft.)
Adjust the light according to
mounting locations. (WALL
MOUNT, EAVE MOUNT, or
BOX MOUNT)
SET WALL SWITCH TO
ON
SET WALL SWITCH TO
ON
Fig. 2
SET WALL SWITCH TO
ON