Behringer 1033 Guia De Inicio Rapido página 3

Ocultar thumbs Ver también para 1033:
Tabla de contenido
4
DUAL ENVELOPE GENERATOR MODULE 1033
Dual Envelope Generator Module 1033 Controls
(1) (2)
(3)
(4)
(5)
(6)
(7)
(8)
(9) (10)
(11)
(12)
Controls
SUSTAIN LEVEL – Controls the
(EN)
(5)
level at which the envelope
remains after its peak but before
release, sustaining as long as
the input signal is present or the
GATE DELAY – Delays the
(1)
manual gate button is held down.
envelope cycle up to 3 seconds
from initial gate input.
FINAL DECAY TIME – Controls
(6)
how quickly the envelope falls
SIGNAL LED – Indicates when a
(2)
after the input signal stops or the
gate signal is present.
manual gate button is released.
ATTACK TIME – Adjusts the rate
(3)
TRIGGER MODE – Selects
at which the envelope reaches its
(7)
peak voltage.
between single mode,
where only the gate signal
INITIAL DECAY TIME – Adjusts the
(4)
controls the envelope,
rate at which the envelope decays
or multiple mode, which uses a
from its peak to its designated
positive trigger pulse to re-trigger
sustain level.
the envelope while a gate signal
is present.
NIVEL DE SOSTENIMIENTO –
(5)
Controles
(ES)
Controla el nivel en el que
permanece la envolvente después
de su pico pero antes de soltarse,
manteniéndose mientras la señal
RETRASO DE PUERTA – Retrasa
(1)
de entrada esté presente o se
el ciclo de la envolvente hasta 3
mantenga presionado el botón de
segundos desde la entrada inicial
puerta manual.
de la puerta.
TIEMPO FINAL DE DEMANDA –
(6)
LED DE SEÑAL – Indica cuando
(2)
Controla la rapidez con que cae
está presente una señal de puerta.
la envolvente después de que se
detiene la señal de entrada o se
TIEMPO DE ATAQUE – Ajusta la
(3)
suelta el botón de puerta manual.
velocidad a la que la envolvente
alcanza su voltaje máximo.
MODO DE DISPARADOR –
(7)
TIEMPO INICIAL DE DESCENSO –
Selecciona entre modo único,
(4)
Ajusta la velocidad a la que la
donde solo la señal de la puerta
envolvente decae desde su pico
controla la envolvente,
hasta su designado
o modo múltiple, que utiliza un
sostener el nivel.
pulso de disparo positivo para
volver a disparar la envolvente
mientras hay una señal de puerta.
5
Quick Start Guide
MANUAL GATE – Press and hold
(8)
to start the envelope cycle.
GATE– Connect a gate signal to
(9)
control the envelope cycle.
TRIG – Triggers a new attack of
(10)
the envelope if a gate signal is
also present.
OUT L – Send the left envelope
(11)
positive and negative control
voltages to other modules via
3.5 mm TS cable.
OUT R – Send the right envelope
(12)
positive and negative control
voltages to other modules via
3.5 mm TS cable.
PUERTA MANUAL –
(8)
Mantenga pulsado para iniciar el
ciclo de envolvente.
PORTÓN – Conecte una señal de
(9)
puerta para controlar el ciclo de la
envolvente.
TRIGONOMETRÍA – Activa un
(10)
nuevo ataque de la envolvente si
también está presente una señal
de puerta.
FUERA L – Envíe los voltajes de
(11)
control positivo y negativo de
la envolvente izquierda a otros
módulos mediante un cable
TS de 3,5 mm.
FUERA R – Envíe los voltajes de
(12)
control positivo y negativo de
la envolvente correcta a otros
módulos a través de un cable
TS de 3,5 mm.
Tabla de contenido
loading

Tabla de contenido