Heath Zenith Dual Brite SL-5512 Manual Del Usuario página 3

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

TEST AND ADJUSTMENT
❒ Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1
fore it will detect motion. When first turned on
or when switching modes wait 1
❒ Turn the RANGE control to the mid position, Dual
Brite™ to OFF and the ON-TIME control to the
TEST position.
MAX
ON - TIME
MIN
TEST 1 5 2 0
RANGE
MINUTES
Bottom of Sensor
Avoid aiming the sensor at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
• Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
8 ft.
(2.4 m)
70 ft.
(21 m) (30.5 m)
Maximum Range
The detector is less sensitive to motion directly towards it.
Motion
Sensor
Least Sensitive
595-5575-06
/
minute warm up period be-
1
2
/
minutes.
1
2
DUAL BRITE
OFF 3 6 DUSK TO
HOUR DAWN
100 ft.
Boosted
Maximum
Coverage Angle
Motion
Most Sensitive
❒ Loosen the clamp screw in the
sensor ball joint and gently
rotate the sensor.
❒ Walk through the coverage
area noting where you are
when the lights turn on. Move
the sensor head up, down, or
sideways to change the cover-
age area.Keep the sensor at
least 1" (2.5 cm) away from
the lamps.
❒ Adjust the RANGE as needed.
RANGE set too high may
increase false triggering.
❒ Secure the sensor head's
aim by tightening the clamp
screw. Do not overtighten the
screw.
❒ Set the amount of TIME you
want the lights to stay on after
motion is detected (1, 5, or 20 minutes).
❒ Set the DUAL BRITE™ switch to the amount of
time after dusk you want the lights on at low level
(Off, 3, 6 Hrs., Dusk-to-Dawn).
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft.
240°
Sensing Angle . . . . . . Up to 240°
Electrical Load. . . . . . Up to 300 Watt Maximum Incan-
Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL
Time Delay . . . . . . . . 1 , 5, 20 minutes
Replacement lamp. . . T3, 150W halogen maximum
Dual Brite™ Timer . . . Off, 3, 6 hours, Dusk-to-Dawn
DESA Specialty Products™ reserves the right to dis-
continue products and to change specifications at any
time without incurring any obligation to incorporate new
features in products previously sold.
3
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
(30.5 m) with Range Boost.
[var ies with surrounding
temperature]
descent [Up to 150 Maximum
each lamp holder].
MODE
120 VAC
Clamp
Screw
Ball
Joint
Tabla de contenido
loading

Este manual también es adecuado para:

Sl-5512

Tabla de contenido