LWT temperatures. (Only available in installations with gateway AZX6GAW[XXX] provided that the aerothermal unit is
not configured to work automatically, allowing the imposition of working temperatures). It allows to set the LWT
temperaturas for the heatting and cooling modes of the aerothermal unit. Selectable values depends on each
particular aerothermal unit. Default presets are:
-
Air in cooling mode: 10 ˚C
-
Radiant in cooling mode: 18 ˚C
-
Air in heating mode: 50 ˚C
-
Radiant in heating mode: 35 ˚C
•
DHW function. (Only available in installations with AZX6GAW XXX control gateways) It allows to turn on/off the Domestic
Heat Water (DHW) function in the systems connected to the CCP. Activated by default.
•
Cooling mixing valve (only available in installations with aerothermal gateway). It allows you to configure the
operation of your installation depending on whether or not you have a cooling mixing valve.
Select Manual in the case of having cooling mixing valves in your installation, in which case they must be set at 18°C.
If the installation does not have a cooling mixing valve, select Auto so that the installation works automatically with
the temperature read by the system. By default it is set as Manual.
WEBSERVER CONFIGURATION
When the Airzone cloud production control board is connected to the Main Control Board, a new item appears in the user
menu. From the main screen, press the icon
Status Menu
, select the Information parameter
The status menu
, gives information about the MAC and PIN of the device, as well as the
connection status:
The internet connection is correct.
There is no internet connection, check the connection between the Production Control
Board and the router as well as the status of the router.
and press the Webserver menu.