General reset
General-reset
Put DIP switch 4 to
Push reset button
ON
All factory settings are restored by the general reset !
Factory settings (default settings):
 all memory slots erased
 switching time = 5 sec.
 lock-out time = 20 sec.
Put DIP switch
on the PCB
back to OFF
> 5 sec.
Lock-out function:
If the lock-out function is activated, the Cody Light HF door opener
automatically blocks any input for a set period (20sec.) after the input
of a wrong pass code which is signalled with a (3 beeps) sound signal.
The end of the blocking time is signalled by a long sound signal.