2 Mount the Wall Plate
Solid concrete or concrete block
2-1 Mark the wall
≥177.8 mm
(7 in.)
2-2 Drill pilot holes
2-3 Insert anchors and lag bolts
[21]
6901-002080 <03>
[01]
[21]
[01]
[22]
[20]
For assistance in determining wall plate location, see Height Finder at
sanus.com.
Level the wall plate [01] and mark the hole locations.
CAUTION:
Avoid potential injuries or property damage!
Mount the wall plate [01] directly onto the concrete surface.
Minimum solid concrete thickness: 203mm (8 in.).
Minimum concrete block size: 203 x 203 x 406 mm (8 x 8 x 16
in.).
Minimum horizontal space between fasteners: 177.8 mm (7 in.).
CAUTION:
Avoid potential injuries or property damage!
Pilot holes MUST be drilled to a depth of 89 mm (3½ in.) using a
10 mm (3/8 in.) diameter drill bit.
Never drill into the mortar between blocks.
89 mm
(3½ in.)
Insert lag bolt anchors [21]. Then insert lag bolts [20] through the
washer [22], wall plate [01], and into the anchors.
CAUTION:
Improper use could reduce the holding power of the
lag bolt. To avoid potential injuries or property damage:
13 mm
10 mm
(1/2 in.)
(3/8 in.)
Be sure the anchors [21]
are seated fl ush with the
concrete surface.
Tighten the lag bolts [20]
only until the washers [22]
are pulled fi rmly against the
wall plate [01].
DO NOT over-tighten the
lag bolts [20].
9