DE
Gebrauchsanweisungen und Ratschläge
FR
Instructions et conseils
IT
Avvertenze e suggerimenti
Troubleshooting
Problem
The fan doesn't rotate
EN
The fan rotates
without ventilating the
inside of the vehicle
* Ensure that the power supply has been disconnected before carrying out any kind of operation,
than reconnect.
Cause
Power voltage is less
than 8 Vdc
The cables are
incorrectly connected
Foreign bodies are
blocking the blade
Power failure
Thermostat has
intervened (if it is present)
The room temperature
is under -10°C
None of the above
causes
Deviator in exhaust position
COMFORT
EN
Maintenance instructions
ES
Recomendaciones
Charge the battery, check
that the voltage is 12 Vdc
Check that connections
correspond to wiring
diagram*
Remove any obstructions
from the blade*
Check the fuses in the
main control panel*
Lower the intervention
point of thermostat
Raise the room temperature
at a degree over the -10°C
Contact your Fiamma
Service Centre
Set the deviator to
ventilation mode
Solution
25