Caution
Air vents must not be blocked and must have free access to the room
ambient air for cooling.
7.
If you purchased a redundant power supply (RPS) unit for the switch,
connect the RPS unit to the R.P.S. Input connector (Figure 3) on the rear
of the switch by following the directions included with the RPS system.
Caution
If you intend to use a redundant power supply (RPS) with the switch,
check to be sure that the cable with the RPS unit is compatible with the
RPS Input Port on the switch. The pin assignments for the connector
are provided in the section Table 5 on page 11.
Warning
The power cord is used as a disconnection device. To de-energize
equipment, disconnect the power cord.
8.
Apply AC power to the switch by plugging the power cord into the AC
power connector on the back panel of the unit (shown in Figure 3) and
plugging the other end into a power outlet.
As power is applied to the switch, the Fault LED (shown in Figure 4)
flashes as the switch runs a series of internal self tests. Refer to the
sections "Switch LEDs" on page 9 for information on the system LEDs.
9.
Connect the data cables, making sure each connection has a good valid link
and that the switch is receiving packets.
10. Go to the procedure "Setting Up for Local Management" on page 8 to access
the Omega management software on the switch.
!