Application - Bosch Thermotechnik JUNKERS TA 210 E Manual Del Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

TA 210 E
1

Application

The TA 210 E is a weather controlled feed
water temperature regulator for installation in
the switch box of the following gas heating
equipment:
Unit:
"Thermen" Heating Boilers:
ZR/ZWR/ZSR...-3
ZR/ZWR/ZSR...-4
ZV/ZWV 20 A
ZWE...A
Central Heating Boilers:
KSN...-7...*)
KNS...-7...*)
KS...-7...
KNH...-7...*)
*)
TA 210 E already installed
(for KSN/KNS..-7, only in the EC model)
The parts supplied with the TA 210 E include
not only the regulator with cover, seal and
sticker but also an outdoor temperature sen-
sor with mounting material (Figure
regulator is connected within the switch box
of the heating unit.
On the feed of floor heaters, an additional
mechanical controller must be fitted accor-
ding to the information of the manufacturer.
This mechanical controller is not a part of
the equipment supplied. The connection in-
structions can be found in the installation in-
structions of the heating equipment.
The TA 210 E is supplied without a time con-
trol. This is available as an accessory. A re-
mote control with a time control can also be
used (see below).
The following combinations are permitted:
"Thermen" Boilers:
TA 210 E + EU 3 T
TA 210 E + EU 2 D
TA 210 E + EU 3 T + TW 2
TA 210 E + EU 2 D + TW 2
TA 210 E + TFQ 2 T/W
TA 210 E + TFP 3
Figure
Figure 6/7
Figure 6/7
Figure 6/7
Figure 6/7
Figure 8/9
Figure 8/9
Figure 8/9
Figure 8/9
3
). The
Electrical Circuit
Diagram
Figure 12
Figure 12
Figure 13
Figure 13
Figure 14
Figure 14
Central Boilers:
TA 210 E + EU 3 T
TA 210 E + EU 2 D
TA 210 E + EU 3 T + TW 2
TA 210 E + EU 2 D + TW 2
TA 210 E + TFQ 2 T/W
TA 210 E + TFP 3
Note: According to Par. 7 of the Heating Sy-
stem Regulations, the TA 210 E can be ope-
rated only in conjunction with a time control.
The Figures
/
("Thermen" boilers) and
6
7
8
/
9
(central boilers) show schematically
the use of the TA 210 E for a radiator or a
floor heater.
Legend for Figures
P
= Circulation pump
I
UP
= Circulation pump, heating circuit
HK
LP
= Filling pump, warm water tank
B1
= Thermostat, warm water tank
B2
= Feed water temperature limiter
(only for floor heaters)
FB
= Remote control TW2, TFQ2 or
TFP3 according to the table above
AF
= Outdoor temperature sensor
RK
= Check flap
E
= Air bleed valve
SV
= Safety valve
ÜV
= Overflow valve
MAG = Membrane expansion vessel
A
= Branch box
SP
= Warm water heater
Electrical Circuit
Diagram
Figure 15
Figure 15
Figure 16
Figure 16
Figure 17
Figure 17
to
:
6
9
5
Tabla de contenido
loading

Este manual también es adecuado para:

7 719 000 790