DECLARATION OF CONFORMITY

Galletti S.p.A., whose main office is in via Romagnoli 12/a,
40010 Bentivoglio (Bologna) - Italy, hereby declares, under its
sole responsibility, that the FLAT fan coil, indoor units for heating
and air conditioning systems, conform to the specifications of
the Directives 2006/42/EC, 2004/108/EC, 2006/95/EC and
subsequent amendments.
Bologna, 03.02.2016
Luca Galletti
President

SAFETY SYMBOLS

Carefully read
WARNING
this manual
1
BEFORE STARTING THE INSTALLATION
PROCEDURE
Carefully read this manual.
Installation and maintenance may be carried out solely by qualified techni-
cians specifically trained for this type of equipment, in conformity with
current regulations.
On receiving the equipment, check that it has not undergone any damage
during transport.
For installation and use of accessories, please refer to the relative technical
sheets.
Identify the model of the FLAT S fan coil following the indications on the
packing container.
2
INTENDED USE AND OPERATING LIMITS
Galletti S.p.A. will not accept any liability for damage or injury caused as a
result of installation by non-qualified personnel; improper use or use in condi-
tions not allowed by the manufacturer; failure to perform the maintenance
prescribed in this manual; use of spare parts other than original factory parts.
The operating limits are specified below; usage outside the stated limits is
to be considered improper:
- thermal carrier fluid: water
- water temperature: from 5°C to 80°C
- maximum water pressure during operation: 10 bar
- air temperature: from 5°C to 43 °C
- supply voltage: 230 V 50 Hz
When choosing an installation site, you should observe the following rules:
- The air conditioning unit should not be placed immediately under a socket
- Do not install the unit in places where inflammable gases or powders are
present
- Do not expose the unit to sprays of water
- Install the fan coil on walls or ceilings able to withstand its weight. Keep
a clear space all around the unit to assure the proper functioning and ac-
cessibility for maintenance
- Store the unit in its packing container until you are ready to install it to
prevent dust from infiltrating inside it.
3
Compact design fan coils with centrifugal fan
FLAT S 2.8 kW
Galletti FLAT S: performance and design in a single indoor unit
FLAT S by Galletti has been engineered to offer performance and design
features placing it at the top of its category.
The uniqueness of FLAT S lies both in the use of extremely high quality
materials - which contribute to making this product exceptionally robust - and
the assurance of constant performance over time. The compact dimensions
make it particularly easy to be integrated in any context.
FLAT S optimizes the distribution of air in the room thanks to the integrated
air outlet grille which makes it possible to direct the treated, filtered air in 4
directions.
The main flap is equipped with a microswitch which shuts off the fan and
the valves when the flap closes. The flap is useful for avoiding dust build-up
Use individual pro-
in periods of non-use.
tective devices
The adoption of UV-stabilized ABS in the parts making up the cabinet and
antistatic ABS in the fan assembly (volute and centrifugal fan) guarantee that
the product will maintain the same aesthetics and noise levels throughout
its lifetime. Particular care has been taken in the design of the fan drive
assembly, which guarantees exceptionally quiet operation in the version
with 3-speed motors.
AVAILABLE VERSIONS
FLAT S
Suspended wall installation,
with cabinet, with vertical air
flow.
ERGO
Supervi-
* 4 pipes on request
PLUS
- Cabinet with a refined design
- Use of UV-stabilized ABS
- Reversible water connections
- 3-speed motor
- ABS centrifugal fans
- Can be integrated into ERGO
- Incorporable ioniser
9
All copying, even partial, of this manual is strictly forbidden

UNIT DESCRIPTION

2
2-pipe
Vertical
Centrifu-
systems*
installa-
gal fan
sion
tion
EN
VERSIONS
FLS 1 XX
VARIANTS
SIZES 10÷40
FC66004073- 00
Tabla de contenido
loading

Este manual también es adecuado para:

Flat s 10Flat s 20Flat s 30Flat s 40