NOTES:
Dimension for depth depends on the wall thickness and
the type of molding.
Do not block louvers in the air conditioner cabinet.
Use 1" (2.5 cm) or thicker lumber for the wood frame.
A. Outside width
B. Outside height
C. Depth
4. Apply the wood preservative to the outside exposed surface.
5. Insert the frame in the wall opening. Square and level the
frame.
6. Attach the frame securely to the wall.
Install Cabinet into Wood Frame
1. Insert the cabinet into the framed wall opening.
NOTE: Handle the air conditioner gently.
1. Make sure the free end of the ground wire is outside of the
cabinet.
WARNING
Excessive Weight Hazard
Use two or more people to move and install
air conditioner.
Failure to do so can result in back or other injury.
2. Insert the air conditioner into cabinet.
10
A
B
C
A
A. Trim
Complete Installation
2. Use a level to check that the cabinet is level side to side.
3. Check that the air conditioner cabinet is tilted to the outside
so that water will run to the outside.
Complete Through-the-Wall Installation
1. Reuse the insulation to seal opening between the cabinet and
the frame.
2. Use the existing holes and 6 - #10 x 1" wood screws (not
provided) to attach the cabinet to the frame.
NOTE: Do not overtighten the screws or the cabinet will
distort and provide a poor air seal between the cabinet and
the air conditioner.
3. Caulk all outside wall openings around the cabinet.
NOTE: Make sure the free end of the ground wire is outside
of the cabinet.
A
A. Ground wire outside of the cabinet
A
A. Level