PRE-FLASHING
C4
SAFETY DEVICES TEST
C5

LIMIT SWITCH

C6
DECELERATION
C7
HAMMER STROKE
Y
Enables 3-second pre-flashing before motor start
Disables pre-flashing.
N
The flashlight and the motors start at the same time.
Enables the safety devices test. See also menu C20.
When the device is activated (edge intercepted), the writing SAF
appears on the LCD
Operation:
PHASE 1: when the Start or the Pedestrian command is given, the
amperometric circuit is tested. If an anomaly is detected, it will be
indicated by 4 long flashing (2 sec.) of the flashing light.
PHASE 2 : If the edge with N.C. contact is enabled, when the Start or
Y
Pedestrian command is given, the power to the safety devices is cut off
for 0,5 seconds and then restored: if the inputs of the safety devices
open and immediately return N.C., the motors start, otherwise a fault is
signalled with 3 long flashes (2 sec.).
PHASE 3 : if the edge 8K2 is enabled, when the Start or the Pedestrian
command is given, the SAFETY DEV. Input is tested (value 8K2). If the
value is not correct, the fault is signalled with 2 long flashes (2 sec.).
WARNING: The indication of the fault detected will be only one (the first
one to be detected) even if there is more than one fault.
N
Disables the safety devices test.
Enables the single limit switch reading.
E1
See the paragraph "LIMIT SWITCHES USE"
Enables the double limit switch reading.
E2
See the paragraph "LIMIT SWITCHES USE"
Disables the limit switch reading.
N
Enables the deceleration function
Y
Disables the deceleration function
N
Enables the hammer stroke function to allow the electrical lock
release.
Operation:
When the Start command is given, the sequence is:
Y
- Electrical lock activation
- Start motion in closing for 1 s
- opening
- after 2 s electronical lock release
Not activated with the sliding configuration
Disables the hammer stroke function
N