UK
STEP BY STEP
A6
WITH STOP LOGIC
A7
STEP BY STEP LOGIC
AUTOMATIC/
A8
CONDOMINIUM LOGIC
It enables the STEP BY STEP WITH STOP logic
Operation:
Start
Next Start
Next Start
Next Start
If automatic closing has been activated (menu C1) and the opening
E
phase is at the end of the cycle, when the pause time has elapsed
(menu H9), the control unit automatically closes the gate.
If the gate is open "Start" closes the gate.
Pedestrian is uninfluential during opening. It will be active in pause if
the pedestrian automatic closing is disabled. In closing, it opens 1 or 2
leaves depending on menu C14.
The activation of this menu automatically disables A7-A8-A9.
It enables the STEP BY STEP logic
Operation:
Start
Next start
Next start
If automatic closing has been activated (menu C1) and the opening
Y
phase is at the end of the cycle, when the pause time has elapsed
(menu H9), the control unit automatically closes the gate.
If the gate is open, "Start" closes the gate.
Pedestrian is uninfluential during opening. It will be active in pause if
the pedestrian automatic closing is disabled. In closing it opens 1 or 2
leaves depending on menu C14
The activation of this menu automatically disables A6-A8-A9.
It enables the AUTOMATIC/CONDOMINIUM logic
Operation:
Start
Next start(s)
Y
When the pause time has elapsed:
If the automatic closing is activated, the system closes automatically.
If the automatic closing is not activated, a "Start" or a Pedestrian
command close the gate (if the opening is pedestrian).
Pedestrian is uninfluential during opening. It will be active in pause if
the pedestrian automatic closing is disabled. In closing it opens 1 or 2
leaves depending on menu C14.
The activation of this menu automatically disactivates A6-A7-A9.
open
stop
close
open
open
close
open
open
uninfluential if the system is
opening, or it reset the pause
time (if the gate is in pause
and the automatic closing is
activated).
BA24