SSS Siedle LNG 600-0 Manual De Instrucciones página 4

Ocultar thumbs Ver también para LNG 600-0:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 10
English
Application
Power line rectifier in the switch
panel housing for the central supply
of LED modules and bus video
panels.
Application
The LNG 600-... is intended to
supply the bus video panels and LED
modules. Any other application is
deemed not in accordance with its
intended use and exonerates the
manufacturer from any liability.
Note
One LNG 600-... supplies max. 3
BVPS/BVPC 850-... devices
Electrical voltage
Mounting, installation and servicing
work on electrical devices may only
be performed by a suitably qualified
electrician.
Failure to observe this regulation
could result in the risk of serious
damage to health or fatal injury due
to electric shocks.
• Observe DIN EN 60065! In a
building installation, an all­pole
mains switch with a contact opening
of at least 3 mm must be provided.
The device must not be exposed
to water drops or sprayed water!
Sufficient ventilation must be
ensured. Pay particular attention to
ensure that ventilation slots are not
covered.
Number
LEDS 600-.../LEDM 600-...
Current
1
150 mA
2
300 mA
3
450 mA
4
600 mA
4
• For surface mounting, ensure that
"protection against direct contact"
with active parts is provided. For
details, consult VDE 0100/DIN 57100
part 410.
• When using stranded cores as
cable material, these must be fitted
with wire end ferrules without fail.
Scope of supply
• Line rectifier for distributor
mounting 6 TE
• This product information sheet
Mounting in distribution cabinet
1 Mount the line rectifier on the top
hat rail (distribution).
2 Surface mounting is possible with
accessory ZAP 6-0. (not included in
scope of supply)
Surface mounting
Surface mounting is only possible
with accessory ZAP 6-0. Clip the
provided latches onto the back of
the LNG 600-... Mount the device
on the wall.
Terminal assignment
L1, N
Power connection
+, –
Voltage 30 V DC
Installation
The LNG 600-... is able to supply
several lights on a parallel basis. The
number differs depending on the
type of lights used.
LEDF 600-3...
Range
Current
830 m/2722 ft
260 mA
415 m/1368 ft
520 mA
275 m/902 ft
205 m/672 ft
Depending on the number of con­
nected lights, the maximum admis­
sible range of the cable must be
observed (0.8 mm core diameter).
The table shows the maximum
number of lights with the admissible
range.
Illuminated information sign
Steel
Size
(mm)
154 x 154
168 x 168
308 x 308
462 x 462
518 x 518
Remedying faults
The line rectifier is electronically
fused and switches off in case of an
overload or short circuit.
Specifications
Operating voltage: 100–240 V AC,
+/-10 %, 50/60 Hz
Operating current: 0.3 A to 0.7 A
Output voltage: 30 V DC
Output current: 1.1 A DC
Ambient temperature:
0 °C to +40 °C
Protection system: IP 20
Horizontal pitch (HP): 6
Dimensions (mm) W x H x D:
107 x 89 x 60
LEDF 600-4...
Range
Current
480 m/1574 ft
335 mA
240 m/787 ft
Current
Range
(mA)
(m)
125
750
125
750
215
550
375
300
425
250
Range
370 m/1214 ft
loading