INSTALLATION
5) Installation of emergency opener without external control:
a) Apply the main mechanism with spring latch on the door profile and fix it with 4 Ø3,9 self-tapping screws.
To eliminate the side spring latch from the modular mechanism insert the cap (Z) between the spacer plate and
the mechanism before tightening the screws.
To eliminate the side spring latch from the modular mechanism insert the cap (Z) between the spacer plate and
the mechanism before tightening the screws.
b) make two Ø3 holes at the two slots in the rear support, maintaining the reference to the horizontal axis "T-T",
and fix the rear support with two Ø3.9 screws
c) refit the rear push-button cap on the bar and refit the rear cover on the support
d) fit the cover on the mechanism and secure it with the screws
e) tighten the screws of the round connection shim.
6)
Installation of emergency opener combined with External Control:
a) Join the external control and the plate supplied using the M5 metric screws in the pack
b) Apply the mechanism with the spring latch on the door profile and fix it with 4 Ø3,9 self-tapping screws.
c)
carry out the steps described in points b) to e)
d)
for installation of the External Control, refer to the relevant instruction sheet in the pack.
Fig. 7
" T - T "
b
c
ISTRUZIONI - INSTRUCTIONS - INSTRUCTIONS - INSTRUCCIONES
a
(Z)
e
d
- 17/40 -