Self-calibration:
If the gate travel parameter is changed, there is no need for the installer
to run new calibrations, however, when changing the travel parameters,
the control panel needs to learn the current curve again, thus disabling
the obstacle detection only during the self-calibration cycle. Self-calibra-
tion is appropriately highlghted on the display that shows 51, meaning
that a command is required in order for the board to self-calibrate.
The events generating self-calibration are:
- change in parameters: P09-10-11-12-13-14-15-16-17-18-19-20-21-22-
25-26-31-36-43.
Board parameters
Sub
Description
menu
Auto close
P01
Auto close not active
Auto close active
Pause time
2 s (minimum time)
P02
600 s (maximum time)
Command input n. 51
Collective
During the opening the command is not active.
If P01 = ON when paused it restarts the pause
time and if the input 51 remains engaged the
control board suspends the count until the
input is disengaged (for the connection of coils
or timers)
P03
if P01 = OFF, when paused it closes back
During the closing it opens again
Step-bystep (4 steps logic)
Cycle command Opens, Stops, Closes, Stops,
Opens...
Step-bystep (2 steps logic)
Cycle command Opens, Closes, Opens...
Pre-flash
The flashing light flashes for 3 s before the
gate starts to move
P04
Pre-flash not active
3 s pre-flash active
Immediate closing
Immediate closing not active
If the closing photocell is engaged and re-
leased during the opening or the pause time,
P05
the control unit closes the gate, regardless
of the pause time set, 3 s after the complete
opening or 3 s after the release of the photocell
(depending on whether the release takes place
during opening or pause).
Safety input n. 63
Photocell (PH):
- with the gate stopped, does not allow the
gate to open
- during opening stops the movement and
when released proceeds with opening
- with the gate open, does not allow it to close
and when released will reload the pause time
- on closing stops the movement and when
released reopens the gate
P06
NC safety edge (BAR):
- with the gate stopped, does not allow the
gate to open
- in opening disengages, closes after the
pause time if auto close is active
- with the gate open, does not allow closing
and when released will reload the pause time
- in closing disengages and opens
8.2 KΩ balanced safety edge (8K2):
Same behaviour as the NC safety edge
8
Output 14 type of open gate warning loght
(SCA)
Gate closed: not active
Gate not closed: active fixed
P07
Gate closed: not active
Gate in opening: slow flash
Gate not closed: active fixed
Closing gate: quick flash
Safety input test
Test not active
P08
Test active on input 62
Values
(default)
Test active on input 63
(ON)
Test active on both inputs 62 and 63
OFF
M1 slowdown distance during closing
Knowing that 0 means full closing and 100 full
ON
opening, it shows where M1 switches from
(30)
normal speed to slow down speed on closing
P09
2
No slow down
600
Maximum closing slow down travel
(1)
M2 slowdown distance during closing
Knowing that 0 means full closing and 100 full
opening, it shows where M2 switches from
normal speed to slow down speed on closing
P10
No slow down
1
Maximum closing slow down travel
M1 slowdown distance during opening
Knowing that 0 means full closing and 100 full
opening, it shows where M1 switches from
normal speed to slow down speed on opening
P11
2
All leaf travel on opening at slow down speed
No slow down
3
M2 slowdown distance during opening
Knowing that 0 means full closing and 100 full
(OFF)
opening, it shows where M2 switches from
normal speed to slow down speed on opening
P12
OFF
All leaf travel on opening at slow down speed
ON
No slow down
(OFF)
M1 normal opening speed
OFF
Minimum speed
P13
Maximum speed
M2 normal opening speed
ON
Minimum speed
P14
Maximum speed
(1)
M1 normal closing speed
Minimum speed
P15
Maximum speed
M2 normal closing speed
1
Minimum speed
P16
Maximum speed
M1 opening slow down speed
Minimum slow down speed
* with encoder/without encoder
P17
Maximum slow down speed
2
* with encoder/without encoder
M2 opening slow down speed
Minimum slow down speed
* with encoder/without encoder
P18
3
Maximum slow down speed
* with encoder/without encoder
EN
(OFF)
OFF
ON
(OFF)
OFF
1
2
3
(30)
0
100
(30)
0
100
(70)
0
100
(70)
0
100
(100)
50
100
(100)
50
100
(100)
50
100
(100)
50
100
(50)
15 with *
35 without *
75 with *
70 without *
(50)
15 with *
35 without *
75 with *
70 without *
Tabla de contenido