UTILISATION
the appliance
After use, stop your appliance by pressing
on the on/off pedal and unplug it (fig.8).
Stow the cable by pressing the automatic
cable rewind pedal (fig.9). In the horizontal
position, place the sucker attachment in
the parking position (fig.10a). In the upright

CARE AND CLEANING

IMPORTANT Always turn off and unplug
your appliance before maintenance or
cleaning.
The bag full indicator shows you when the
bag is full or saturated. If you notice that your
vacuum cleaner is less efficient, select the
maximum power and hold the nozzle off the
floor. If the indicator remains red, replace the
bag. Open the cover on your vacuum cleaner
(fig.14). Remove the wonderbag
and dispose of it in a rubbish bin (fig.17).
IMPORTANT Do not reuse the wonderbag,
it is a single use bag
Place a new wonderbag in the bag holder,
using the ring (fig.18). Position the bag and
open it out inside the compartment (fig.19).
Make sure that the bag is in the correct
position before closing the cover.
IMPORTANT Never operate the vacuum
cleaner without a bag.
cartridge or the microfilter*
You can get a new Microfilter* Ref.
RS-RT3077 as a spare part from your
Approved Service Centre. You can also
equip your appliance with a HEPA filter*
Ref. ZR0048 01.
2.1. Change the HEPA* filter cassette
Ref. ZR0048 01
The air we breathe contains particles
that may be allergens: mite larvae and
droppings, mould, pollen, smoke and
animal residues (hair, skin, saliva, urine).
*Depending on model: this is either equipment specific to certain models or available as an optional accessory.
position, place the suction unit in the
parking position (fig.10b).
You can then carry and store your vacuum
cleaner in the park position (fig.13). If your
appliance is equipped with the Compact
System* with folding tubes:
Retract the telescopic tubes
press the «Push» button to open the tube
and fold it.
The smallest particles penetrate deep
into the respiratory system where they
can cause inflammation and cause lung
impairment.
HEPA filters (High Efficiency Particulate
Air) are used to filter out the smallest
particles.
With the HEPA filter, the air released back
into the room is healthier than the air that
is vacuumed.
IMPORTANT Replace the filtration system
(fig.15-16)
once a year.
The HEPA filter cassette Ref. ZR0048 01 is
available from your dealer or Approved
Service Centres.
Open the lid of your vaccuum cleaner
(fig.14). Remove the wonderbag
and then remove the HEPA* filter cartridge
(fig.20)
dustbin.
Fit
(Ref. ZR0048 01) in its compartment (fig.22).
Put the wonderbag back in place. Check
that the Hepa* filter cassette is fitted
correctly before re-closing the cover.
2.2. Change the microfilter* Ref. RS-RT3077
IMPORTANT Change the microfilter once
for every six times the bags are changed
The microfilter Ref. RS-RT3077 is available
from your retailer or from Approved Service
Centres.
Open the cover of your vacuum cleaner
(fig.
Remove the Wonderbag
remove the Microfilter* cartridge
which contains the microfilter
26
and dispose of the cartridge in a
the
new
Hepa*
14).
GB
(fig.11)
and
(fig.15)
filter
cassette
(fig.
15), then
(fig. 20)
(10a)
ref.