SAmPLInG
the scale cannot determine how many pieces are on a
platform without a sample.
1.
Put the objects intended for sampling on the platform.
2. Key in the number of objects. this number will blink
in the UnIt WEIGHt display.
3. Press the SmPL key. the calculated unit weight will
then be shown in the UnIt WEIGHt display and the
number of objects is now shown in the tOtAL cOUnt
display.
4. Put on the remaining objects. the total quantity will
then be displayed.
NOTE: The unit weight is displayed in metric
system form. To get a true reading of your unit
weight, move the decimal three places to the
left. DO NOT change the way it reads on the
scale, this will change your piece count. Also
note that the total weight is correct and does
not need to be changed.
mAnUAL EntRy OF UnIt WEIGHt
Enter a known unit weight by pressing the value first,
followed by the UWS key. you must key in the unit weight
using the metric system form. (move the decimal point
over to the right 3 places).
EXAmPLE: you know your unit weight is .0014 lbs. If you
want to key in the weight manually, you would key in
0.014 and hit the UWS key.
PAGE 3 OF 15
UNIT CONvERSION ChART
Fluid ounces (fl oz)
Ounces
1
US gallons
128
milliliters
0.03381402
Liters
33.81402
Ounces (oz)
Ounces
1
Pounds
16
Grams
0.03527397
Kilograms
35.273952
˚ F to ˚ c
˚ c to ˚ F
UNIT WEIghT
UnIt WEIGHt REcALcULAtInG
the unit weight will be averaged again if you add the
remaining quantity gradually, by several lots. this will
help eliminate errors caused by the possible weight
variation among each object and lead to more
accurate results.
When adding objects to the pan, be sure that the
quantity is LESS tHAn those already on the platform.
An alarm will sound a beep when the unit weight is
averaged again.
LAcK OF UnIt WEIGHt
If the unit weight is no more than 4/5 of the set display
resolution (accuracy) or less than 10 piece sample,
the sample insufficient light will blink in the lower-right
corner of the UnIt WEIGHt display, reminding the user
that the unit weight is too small for accurate quantity
calculations.
If the unit weight is too light, another scale is needed.
continuing to use this scale will result in less accurate
results.
PIEcE cOUntInG OPERAtIOn
MODEL
H-1121
H-1122
H-1123
vOLUME
US gallons (gal)
milliliters (ml)
.0078125
29.57353
1
3785
0.000264172
1
0.2641720
1000
MASS
Pounds (lbs)
Grams (g)
0.0625
28.34952
1
453.5924
0.002204623
1
2.204622
1000
TEMPERATURE
( ˚ F-32) +1.8
( ˚ c X 1.8) + 32
MINIMUM PIECE
WEIghT
SAMPLE WEIghT
.0005 lbs.
0.001 lbs.
0.001 lbs.
Liters (L)
0.02957353
3.785
0.001
1
Kilograms (kg)
0.02834952
0.4535924
0.001
1
MINIMUM
.020 lbs.
.040 lbs.
.080 lbs.
0613 IH-1121