Refer to Fig. #4 for roughing-in dimensions for shower
module K-1617.
36"
(91.4cm)
4. INSTALLATION PREPARATION
RECESS CONSTRUCTION
Study the roughing-in diagram that applies to your specific
installation.
Construct a stud recess according to the roughing-in
dimensions and framing dimensions for the module you
are installing. See Fig. #5 for a typical stud recess. Be
sure the headers are level and square.
If necessary, the module may be installed through an
open side of the recess. After the module is positioned,
the loose partition wall may be lined up with the module
and nailed securely to the stud framing.
B
1010415-2-
35" (88.9cm)
8" (20.3cm)
4-1/2"
(11.4cm)
37-1/4" (94.6cm)
21" (53.3cm)
42" (106.7cm)
76"-1/2"
(194.3cm)
4"
(10.2cm)
1-3/8"
(3.5cm)
1-1/2"
(3.8cm)
3/16" (5mm) R.
3/8"
(1cm) R.
18" (45.7cm)
C L OF SHOWER
ARM (1/2" N.P.S.)
1"
(2.5cm)
C L OF SUPPLY
FITTING
1"
(2.5cm)
K-1617
Fig. #4