6 Operation

5.8 Changing the driving rollers
1
2
3
Fig. 7
NOTICE
• The driving rollers should be changed whenever the wire type or the wire diameter are changed or
• Change or reverse the driving rollers always in pairs
• Observe the groove geometry and the wire diameter.
If required, the wire must be cut through and then fed in again.
 5.7 Feeding in the wire on page EN-11
1 Open cover at the ABIDRIVE CW .
2 Fold pressure lever (1) forward.
3 Swing the the pressure rocker (6) open using the pressure rolls (2).
4 Unscrew locking screws (5) from driving rollers (4).
5 Replacing the driving rollers (3) .
6 Screw in locking screws (5) and close pressure rocker (6) .
7 Fold pressure lever (1) upward.
Re-adjust the required contact pressure via the pressure lever (1) .
8 Close the cover.
This completes changing the driving rollers (3) .
6 Operation
NOTICE
• As the ABIDRIVE CW is integrated into a welding system, the operating instructions of the welding
• The ABIDRIVE CW may only be operated by qualified personnel.
EN - 12
1
6
5
Pressure lever
2 pressure rolls
2 driving rollers
Changing the driving rollers
the driving rollers are worn out.
components, such as welding torch and welding power source, must be observed during operation. In
addition, the safety instructions for the welding process must be observed.
TIG cold wire feeder
2
3
4
2 full-floating axles
4
2 locking screws
5
Pressure rocker
6
Tabla de contenido