Connect the Breakout Cable
The camera's I/O connector provides connection to the camera's acquisition trigger
and strobe output.
CAUTION:
A ferrite is included with the ISC-8405 camera standard
components. To reduce emissions, the ferrite must be attached to the
Breakout cable.
Note:
I/O wiring or adjustments to I/O devices should be performed when
l
the camera is not receiving power.
The Ethernet cable should be unplugged, or the vision controller
l
powered down before making adjustments to the connections at the
far end of the Breakout cable.
Unused wires can be clipped short or tied back using a tie made of
l
non-conductive material.
1. If installing the ISC-8405 camera, attach the ferrite around the Breakout
cable, adjacent to the strain relief on the cable.
2. Connect the Breakout cable's M8 connector to the camera's I/O connector.
3. Connect the trigger and strobe wires to an appropriate device (for example,
a trigger sensor or strobe light).