Ingersoll Rand 2512 Especificaciones Del Producto página 4

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 6
EN
Model
Input
130V AC~50/
2507
60Hz, 75W
230V AC~50/
2507G
60Hz, 75W
Lubrication
Remove hammer case to apply lubrication. Grease the anvil, impact mechanism assembly
and gears. Apply grease evenly and sparingly. An excessive accumulation of grease will
result in sluggish operation. See drawing 16573388 on page 2. Maintenance frequency is
shown in circular arrow and defines as h=hours, d=days, and m=months.
Instructions for Charging Battery
Do not charge the battery pack when the temperature is below 50°F (10°C) or above
104°F (40°C).
Charge new battery packs before using.
Charging time is approximately 60 minutes.
Action
Plug the charger into
the appropriate power
outlet.
Insert the battery pack
into the charger.
Remove battery pack
when ready for use.
EN-2
Battery Charger
Output
9.6-19.2V DC, 2.2A Ni-Cd or Ni-Mh
9.6-19.2V DC, 2.2A Ni-Cd or Ni-Mh
Condition
Power On (Stand-By)
Charging
Temperature (Stand-By),
Charger will remain on
"Stand-By" until the battery
has cooled to a safe charging
temperature.
Not Chargeable, Please
contact the nearest
Ingersoll Rand office or
distributor.
Charge Completed
Battery
No. of
Type
Cells
8-16
8-16
Charger Display
Red LED Green LED
-
Slow Flash
ON
-
Slow
-
Flash
ON
ON
-
ON
10567527_ed4
Capacity
1.8-2.6 A-h
1.8-2.6 A-h
Alarm
(Sound)
°
-
° °
° ° ° (20 s)
° ° ° ° °
Tabla de contenido
loading

Este manual también es adecuado para:

253025072507g2575

Tabla de contenido