FIAP Fungal Active
Installation, connection and alignment
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury. For use, install the transformer at a minimum safety
distance of 2 m from the bank. Choose an installation place for the transformer that is splash-water
protected. Also protect the transformer against sun radiation (max. 40 °C).
Start-up
Connection
Connect the unit and the transformer using the two-pole plug. Fasten the plug using the union nut.
Switching on the unit: Plug the transformer power plug into the socket.
Switching of the unit: Disconnect the transformer power plug.
Note:
Ensure that the water inlet at the unit underside is not impaired.
Maintenance and cleaning
Adhere to the safety instruction! Only use water and a soft brush. Ensure that no moisture can enter
the unit. In order to keep the device in proper working condition, we recommend regular cleaning,
especially of the metal tab that provides contact with the water level monitor. Take the diffuser out of
the water vessel and carefully remove any sediment. Calcium deposits can be removed using proof
vinegar. Be careful not to damage the insulation of the water level monitor while doing this.
Prior to starting work on the unit, disconnect the power plugs of all units in the water!
Cleaning the unit.
Technische Änderungen vorbehalten. Für Druckfehler übernehmen wir keine Haftung. WEEE-Reg. Nr.: DE78152045
FIAP GmbH, Jakob Oswald Str. 16, 92289 Ursensollen
Tel: 09628 9213 0; Fax: 09628 9213 30;
9
www.fiap.com
FIAP Fungal Active
Pull the individual pump upward and off. Pull off the pump lid sideways and pull out the impeller. Clean
all parts under running water. For cleaning the nozzle, remove the nozzle holder from the lid with a
slight twist.
Reassembling the unit
Reassemble the unit in the reverse order.
Storage/Over-wintering
Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean and check the unit
for damage. Store the Water Starlet frost protected and submersed in a water filled container. Do not
immerse the plug.
Disposal
Dispose of the unit in accordance with the national legal regulations.
Remedy of faults
Malfunction
Pump does not switch on
No mains voltage
Insufficient fountain height
Impeller blocked or soiled
Nozzles soiled
The unit floats up
Strainer casing soiled
LED does not light up
Power supply interrupted
Bulb contacts corroded
Technische Änderungen vorbehalten. Für Druckfehler übernehmen wir keine Haftung. WEEE-Reg. Nr.: DE78152045
FIAP GmbH, Jakob Oswald Str. 16, 92289 Ursensollen
Tel: 09628 9213 0; Fax: 09628 9213 30;
Cause
Remedy
Check mains voltage
Check supply lines
Clean impeller
Clean nozzles
Clean strainer casing
Check power supply
Clean contacts
www.fiap.com
10