Kohler K-9055 Guia De Instalacion página 3

Base de ducha de hierro fundido
Ocultar thumbs Ver también para K-9055:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

60" (1524 mm)
3-5/16" (84 mm)
Roughing-In
NOTICE: All dimensions are nominal. The stud opening tolerance is +1/4" (6 mm) and -0 (0 mm).
Carefully measure your fixture before determining enclosure size. When a fire-rated wall is specified,
dimensions are to the inside of the wall board. Some shimming between the stud frame and the fixture
may be required. Dimensions given in the roughing-in information are crucial for proper installation.
Construct the framing and plumbing accurately.
NOTE: If a firewall is required, increase the roughing-in dimensions according to the thickness of the
firewall material. Stud opening dimensions must be measured toward the exposed side of the wall
material.
NOTE: If the unit will be installed against a masonry wall, make provisions for plumbing connections.
Construct a separate frame wall a minimum of 6" (152 mm) from the masonry wall.
NOTE: You must install the shower base to an adequately supported, level subfloor.
Kohler Co.
30" (762 mm)
17-1/4"
(438 mm)
2" (51 mm)
36"
(914 mm)
3-15/16"
(100 mm)
3
9/16"
(14 mm)
30˚
1069570-2-G
Tabla de contenido
loading

Tabla de contenido