Texi Power 550 S / 750 S
8. Errors and debugging
When work of the motor is disrupted, the digital interface on the control panel will show an error code. Error codes and their
solutions can be found in Table 3.
Table 3: Errors
Error
Error definition
code
01
Hardware overload
02
Software overload
03
Voltage too low
04
Voltage too low
05
Voltage too high
Current detection
07
loop circuit fault
08
Motor stalled
11
Synchronizer error
Initial motor angle
12
detection failure
13
HALL sensor error
DSP access failure
14
EEPROM
Protection against
15
exceeding the
speed
Improper work
16
of motor
18
Motor overload
9. Automatic test
In the idle state, press
about 2 seconds. Press
Solution
Turn off power, wait 30 seconds and turn it on again.
If the error persists, contact an authorized service center.
Turn off power. Check the mains voltage. Turn power back on. If the voltage
is correct, and the problem persists, contact an authorized service.
Turn off power. Check the mains voltage. Turn the power back on. If the voltage
is correct, and the problem persists, contact an authorized service.
Turn off power, turn it on again after 30 seconds. If the machine still does not work
or the problem recurs regularly, contact an authorized service.
Turn off the power, check if the plug is correctly inserted in the socket or if it is
damaged or if something was caught by the machine mechanism. If after checking
the error persists, contact an authorized service.
Turn off power. Make sure that the synchronizer is properly connected to the motor
or if the plug is damaged. If necessary, replace the plug. Verify if the settings of
parameter 18 are correct. If, despite this error persists, contact an authorized ser-
vice.
2 - 3 times turn power on and off. If after checking the error persists, contact an
authorized service.
Turn off power. Make sure that the sensor is properly connected to the motor or if
the plug is damaged. If necessary, replace the plug. If, despite this error persists,
contact an authorized service.
Turn off power. Restart one time. If after checking the error persists, contact
an authorized service.
Turn off power, wait 30 seconds and turn it on again. Check if machine works
properly. Verify the settings of parameter 1. If necessary, change it to factory set-
tings (the value of 350 for the TEXI POWER 550 S motor or 250 for TEXI POWER
750 S motor). If after checking the error persists, contact an authorized service.
Turn off power, wait 30 seconds and turn it on again. If the error persists, contact
an authorized service.
Turn off power, wait 30 seconds and turn it on again. If the error persists, contact
an authorized service.
and
combination – it activates the automatic test, consisting of a cyclic engine start, lasting
and
combination again to exit automatic test mode.
EN
7