WARNING Failure to read and follow the operator's
manual and all operating instructions could
result in death, serious injury, and/or property
damage.
WARNING Fuel and its vapors are extremely
flammable and explosive which could cause
burns, fire or explosion resulting in death,
serious injury and/or property damage. Turn
generator engine OFF and let it cool at least 2 minutes
before removing fuel cap. Let spilled fuel evaporate
before starting engine. Always allow space for fuel
expansion.
WARNING Contact with muffler area could cause
burns resulting in serious injury. DO NOT
touch hot parts and AVOID hot exhaust gases.
Items Included:
Operator's Manual (not shown)
You Will Need:
• Utility knife
• 13 mm socket wrench
• 13 mm wrench
• Unleaded fuel
• Safety glasses
Unpack Generator
1.
Set the carton on a rigid, flat surface.
2.
Remove everything from carton except generator.
3.
Open carton completely by cutting each corner from top to bottom.
4.
Ensure you have all included items prior to assembly. If items are
damaged or missing, call 1-800-743-4115.
5.
Leave generator on carton to install the wheels.
Attach Wheels, Support Leg and
Handles
NOTICE Wheels and support leg must be attached prior to adding any
fuel.
1.
Tip generator so that engine end is up.
2.
Slide axle (k) through both mounting brackets.
3.
Slide a wheel (g) over axle.
1
NOTICE Be sure to install wheel with raised hub inboard.
4.
Place a wheel washer (d) on axle and then place an e-ring (c) in axle
groove.
1
CAUTION E-rings could cause eye injury. E-rings could spring
back and become airborne when installing or removing,
resulting in moderate injury. Always wear eye protection
when installing/removing e-rings.
5.
Install e-ring with pliers, squeezing from top of e-ring to bottom of
axle.
6.
Repeat steps 3 through 5 to secure second wheel.
7.
Tip generator so that engine side is down.
8.
Line up holes in support leg (f) with holes in generator frame.
9.
Attach support leg (f) using 2 bolts 20 mm (a) and 2 hex nuts (b).
Tighten with a 13 mm socket wrench and 13 mm wrench.
10.
Attach handle (m) to bracket on generator frame as shown, with a
45mm bolt (r), flat washers (p), nylon washers (q), and lock nut (n).
11.
Repeat step 10 to secure second handle
.
NOTICE DO NOT overtighten. Handles must be able to move up and
down freely.
12.
Return generator to normal operating position (resting on wheels
and support leg).
13.
Loop handle pins (e) on generator frame just above handle brackets.
14.
Raise handles and insert handle pins to move generator.
Connect Battery
WARNING Battery posts, terminals and related accessories contain
lead and lead compounds - chemicals known to the State of California
to cause cancer and reproductive harm. Wash hands after handling.
1.
Cut off tie wrap securing loose end of negative (black) cable (D).
2.
Using an 8 mm wrench, remove bolt (A), lock washer (B) and flat
washer (C) from negative battery terminal.
3.
Slide lock washer (B), flat washer (C) and negative battery cable (D)
over bolt (A).
4.
Reattach bolt to negative battery terminal and tighten.
5.
Verify that connections to battery and generator are tight and secure.
© 2010 Briggs & Stratton Power Products Group, LLC. All rights reserved.
Every effort has been made to ensure that the information in this document is accurate and correct. However, we reserve the right to alter or otherwise improve the product and this document at any time without prior notice and without incurring obligation.
*This generator is rated in accordance with CSA (Canadian Standards Association) standard C22.2 No. 100-04 (motors and generators).
Quick Start Guide
WARNING Running engine gives off carbon
monoxide, an odorless, colorless, poison
gas. Breathing carbon monoxide could result
in death, serious injury, nausea or fainting.
Operate this product ONLY outdoors. DO NOT operate
this product inside any building or enclosure, even if
windows and doors are open.
WARNING Generator voltage could cause electrical
shock or burn resulting in death or serious
injury. DO NOT operate under wet conditions
• Wire cutter
• Pliers
• 8 mm wrench
1
2
1
f
3
2
2
r
3
p
n
m
4
B
A
4
8000 Watt* Generator
Verify Engine Oil Level and Add Fuel
NOTICE Be sure you have attached wheels and support leg prior to this
step.
NOTICE Before starting the engine, check oil level and ensure that
engine is serviced as described in the Operator's Manual.
NOTICE DO NOT use unapproved fuel such as E85.
NOTICE DO NOT mix oil in fuel.
NOTICE DO NOT modify engine to run on alternate fuels.
1.
Move generator outdoors to a flat, level surface.
2.
The generator engine is shipped from the factory filled with oil.
Before starting the engine, remove oil fill cap (E) and check oil level.
3.
Replace and fully tighten oil fill cap.
4.
Clean area around fuel fill cap (F), remove cap.
5.
Slowly add unleaded fuel (G) to fuel tank (H). Be careful not to
overfill. Allow abouat 1.5 (4 cm) of tank space (J) for fuel expansion
as shown.
6.
Replace fuel cap, and let any spilled fuel evaporate before starting
engine
Move Generator to
Safe Operating Location
1.
Move generator outdoors to a flat, level surface, in an area that will
not accumulate deadly exhaust gas. DO NOT place generator where
exhaust gas could accumulate and enter inside or be drawn into a
potentially occupied building. Ensure exhaust gas is kept away from
any windows, doors, ventilation intakes, or other openings that can
allow exhaust gas to collect in a confined area. Prevailing winds and
air currents should be taken into consideration when positioning
generator.
2.
To reduce the risk of exhaust heat or exhaust gases igniting nearby
combustible material, keep at least 5 feet (1.5 m) clearance on all
sides of generator, including overhead.
Start Generator
NOTICE Always unplug the battery float charger (h) before starting the
generator.
1.
Make sure unit is on a level surface. Disconnect all electrical loads
from the generator.
2.
Turn the fuel valve (K) to the "On" position.
3.
Push choke lever (L) to "Choke" position.
4.
Push engine rocker switch (M) to "On".
g
k
5.
Start generator using Electric or Manual starting.
Electric Start:
Press and hold START switch (N) for a maximum of 15 seconds. If
d
engine does not start, pause for 1 minute and repeat.
c
Manual Start:
Pull starter rope handle (P) slowly until resistance is felt. Then pull
cord rapidly to overcome compression, prevent kickback, and start
engine.
13
6.
If engine starts, proceed to step 10.
7.
If engine fails to start, proceed to step 8.
8.
Move choke lever to "Half" choke position, and pull recoil handle
twice.
9.
If engine does not start, refer to operator's manual for detailed
starting instructions.
10.
Slowly move choke lever (L) to "Run" position. If engine falters,
a
move choke lever to "Half" choke position until engine runs
smoothly, and then to "Run" position.
Plug in Items to be Powered
b
WARNING Damaged or overloaded electrical cords could overheat,
arc, and burn resulting in death, serious injury, and/or
property damage. ONLY use cords rated for your loads.
Follow all safeties on electrical cords. Inspect cord sets before
each use.
e
q
1.
Let engine stabilize and warm up for a few minutes after starting.
2.
Plug in and turn on the desired 120 Volt and/or 240 Volt AC, single
phase, 60 Hz electrical loads.
3.
The 120 Volt AC, 20A duplex receptacles (R) are provided with
"push to reset" circuit breakers (T) to protect the generator against
electrical overload.
4.
The 120/240 Volt AC, 30A locking receptacle (U) is provided with
a rocker switch circuit breaker (V) to protect the generator against
electrical overload.
Shut Down Generator
1.
Turn OFF and unplug all electrical loads from generator panel
receptacles. NEVER start or stop engine with electrical devices
plugged in and turned on.
2.
Let engine run at no-load for several minutes to stabilize internal
temperatures of engine and generator.
3.
Push engine rocker switch (M) to "Off" position.
4.
Move fuel valve (K) to "Off" position.
5.
To prepare for storage, refer to Operator's Manual.
C
D
Have Questions?
Do not return to store. We can help.
Call Customer Service Toll-Free 1-800-743-4115
or vist our web site BRIGGSandSTRATTON.COM
6
7
8
9
10
11
12
10
14
14
11
9
5
E
5
6
F
7
H
J
G
8
Exhaust Port
Pointed away from
dwelling openings
9
K
10
L
11
M
12
N
13
P
14
U
V
R
T
206413, Rev C
loading

Resumen de contenidos para Briggs & Stratton 8000

  • Página 1 Quick Start Guide Have Questions? Do not return to store. We can help. 8000 Watt* Generator Call Customer Service Toll-Free 1-800-743-4115 or vist our web site BRIGGSandSTRATTON.COM Verify Engine Oil Level and Add Fuel WARNING Failure to read and follow the operator’s...
  • Página 2 ¿Tiene Preguntas? Guía rápida de inicio No vuelva a la tienda. Podemos ayudarle. Llame gratuitamente al departamento de servicio 8000 vatios* generador al cliente, 1-800-743-4115 o visite nuestro sitio web, BRIGGSandSTRATTON.COM Comprobar el nivel de aceite del ADVERTENCIA Si no se leen y siguen las...