Before Installation; Electrical Connection; Control Unit Power Supply; Remote Control Pairing - hafele Slido F-Flush51 60 Electric 400.50.038 Manual De Instrucciones

Tabla de contenido

2. Before installation

2.1 Prerequisites
• The installation of electrical systems must be performed by specialized personnel.
• The cabinet must be installed stably and perfectly level. Any deformity or instability in the cabinet may pose a risk to user safety
and system operation.
• Check the correct functioning of the sliding system to be combined with the control system and the correct positioning of track limit
stops.
• Each movement bar is equipped with a 4-metre cable for connection to control unit. The control unit power supply cable has a
length of approximately 3 metres including the power adapter. A 110-240V, 50-60Hz, AC power outlet must therefore be accessible
near to where the cabinet is installed.
• The installed electrical system must comply with applicable regulations regarding active and passive electrical protection.

2.2 Electrical connection

Make sure that the power outlet is easily accessible after installing the cabinet and system.
All connections must comply with the regulations of energy supply companies.
3. Set-up operations
3.1 Initial cabinet set-up
Do not power the control unit until all motors have been connected.
Connect all movement bar motors to the control unit according to the chosen cabinet configuration.
After connecting all the motors to the control unit according to instructions, manually bring the doors to their closed positions.

3.2 Control unit power supply

After checking the correct connection of the motors to the control unit and
bringing the doors to their closed positions, the control unit can finally be
powered via the power supply unit.
Wait at least 10 seconds after powering on the unit
to allow it to learn and select the program to use with
the connected system.
00:00:10
3.3 Track memorization cycle
Activate the function for automatic detection of door track limits, as described
in Section 2.3, by long pressing (3 seconds) the 'SET/RESET' button on the
control unit.
One door at a time, starting from the first door to the left of the cabinet, the
doors will move slowly towards their respective track limit stops.
The operation may take up to a few minutes until all door tracks have
been memorized.
During this set-up phase, the movement of the doors must not be impeded
in any way.
If the positions of the track limit stops are changed, the track memorization
cycle must be repeated.
During this set-up phase, the remote control pairing function cannot be
activated.
If this operation is not successful due to a lack of power or physical obstacles
in the path of the door, simply unplug the power supply, bring the doors to their
closed positions and repeat the operation.

3.4 Remote control pairing

To activate the pairing function, press and release the "REMOTE SET" button on
the control unit. Then a red LED will flash on the control unit. While the LED is
flashing, press for at least 3 seconds one of the buttons of the remote control to
pair it.
Multiple control units can be paired and used with a single remote control.
Multiple remote controls can be paired and used with the same control unit.
Pairing must not be activated during the track memorization cycle.
00:00:03
SET
43
en
Tabla de contenido
loading

Este manual también es adecuado para:

Slido f-flush51 60 electric 400.50.039Slido f-flush51 60 electric 400.50.486Slido f-flush51 60 electric 400.50.487Slido f-flush51 60 electric 400.50.488

Tabla de contenido