Device description

Installation
• The device may only be installed by trained personnel
• The installation must ensure that
– no excess (heat) residue builds up
– the device is not subject to jets of hot air from another device
• Protect the device from mechanical vibrations and shocks
• For installation dimensions, see pages 3, 4 (Size)

Air supply

• As air supply, suitable blowers have to be used (pay attention to the direction of rotation).
• In order to protect the heating element, the specified minimum air volume must never be fallen below and the ma-
ximum temperature (hottest point measured 3 mm in front of the heating element tube) must never be exceeded
(see technical data). If the minimum air volume is fallen below, the heat output must be interrupted immediately.
• Air Heater type DF may only be supplied with air up to max. 150 °C / 302 °F.
• Observe direction of air flow.
• For use in a dusty environment the tool should be fitted with a Leister stainless steel filter on the air intake
connection. Where a particularly critical dust problem exists (e.g. metal, electrically charged or damp dust)
special filters must be used to avoid short circuiting the tool.
Connection
• The air heater must be connected by qualified personnel.
• A suitable device for full disconnection from the mains with a contact distance of 3 mm must be provided in
the mains connection.
• The power supply cord should have the corresponding cross section area of conductor and should be fitted by a
specialist.
• The device must be connected in accordance with the connection on page 5 (Wiring Diagram) of the operating
instructions.
• Only the installed temperature-resistant special cord may be used for the electrical connection.
• It must be ensured that the power supply cord is protected against mechanical strain when routing it.
• It must be ensured that the connection lines do not come into contact with the heating element tube and are not
exposed to the hot air jet.
• Connect air heater to the electrical mains.
• It must be ensured that the hot air can flow out freely, as otherwise the device can be damaged by the excess
heat building up (risk of fire!).
• Attention: comply with minimum air volume and maximum air temperature as per technical data.
• Switch on mains.
• Allow device to cool down after heating mode.
12
Heating element
tube with air outlet
Attention: always operate device with air supply !
Cable gland
Air intlet