S FETY PREC UTIONS
•
voiding water damages: It is advisable to watch the
filter closely for the first couple of days upon instal-
lation, as to make sure the hose connections are
100% water proof.
• The sera fil bioactive external filter must be placed
in a safe dry spot outside the aquarium, just below
the water surface level. Never place the unit any
lower than 1.5 m (60 in.) below the water surface
level.
• Do not submerge in water.
• Operate filter only indoors.
• Never operate without or without sufficient water
flow.
• Disconnect this and all other electric devices from
the power/mains supply especially when working
within the aquarium (water) or on the sera fil bioac-
tive.
• Protect the power/mains plug against moisture and
dripping water.
• The sera fil bioactive external filter must be used
only for the indicated purpose.
• The temperature of the water to be pumped must
not exceed 35°C (95°F).
• Ensure that the electrical plug of the switched-on
unit is freely accessible at all times.
Troubleshooting
Problem
Filter does not pump water
Pump performance is very low
Recommendations
•
dditionally secure all hose connections with stain-
less steel hose clamps.
•
lways carry the filter by supporting the bottom.
Never lift it by the filter head, its external parts or its
hose connections.
• Replace all hoses and the filter head seal every
2 years. Grease the filter head seal with Vaseline
every time before you close the filter.
• Place the filter into a plastic bowl. Direct a hose and
cable loop into the bowl to avoid damage caused by
dripping water.
• Damage of the pump head, the cable or the plug
must not be repaired! In this case the filter must
immediately be disconnected from mains supply,
and must not be operated any more. This is also
applies in case of intended alterations of these
parts. This kind of damage must not be repaired or
mended. In case of damage or leakage at the filter
case, at the seals, or in the parts that contain water,
the filter must immediately been taken apart and
repaired.
• The filter must be connected with a fault current
protection switch (RCD 30 m ).
Warning
1. Children should be supervised to ensure that they
do not play with the appliance.
2. This appliance is not intended for use by persons
(including children) with reduced physical, sensory
or mental capacities, or lack of experience and
knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a
person responsible for their safety.
3. If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
Possible cause
Too much air inside the filter
No electrical supply
Rotor does not move
Outlet valve is not open
Too much air inside the filter
Filter is clogged
Technical Data:
Only for /C 220 – 240 V ~ 50 Hz
Model:
Max. aquarium size:
Max. water flow:
Power uptake:
Number of filter media baskets: 2
Dimensions (W x H x D):
IPX4
18
Possible solution
Use pump handle, if necessary
open and fill with aquarium water
by 3/4
Connect to power/mains supply
Take off filter head and clean
Throw multi-purpose handle (4.5)
Use pump handle (4.10)
Clean filter, if necessary replace
filter media with new ones
130
130 l
(34 US gal.)
300 l/h
(79 US gal./h)
11 W
223 x 304 x 223 mm
(8.8 x 12 x 8.8 in.)